The performance of SD Bioline rapid antigen test (RAT) was evaluated using real-time reverse transcription polymerase chain reaction (rRT-PCR) as gold standard. A total of 718 nasal swabs, including 102 rRT-PCR positive and 616 rRT-PCR negative swabs, were tested. RAT demonstrates a sensitivity of 29·4% with a specificity of 100%. The positivity rate of RAT was highly associated with lower cycle threshold (Ct) values (P < 0·0001). The excellent specificity of the RAT allowed for the rapid identification of influenza cases. However, negative results should be verified by rRT-PCR test because of limitations observed in sensitivity.
采用实时逆转录聚合酶链反应(rRT-PCR)作为金标准,评估 SD Bioline 快速抗原检测(RAT)的性能。共检测了 718 份鼻拭子,包括 102 份 rRT-PCR 阳性拭子和 616 份 rRT-PCR 阴性拭子。RAT 的灵敏度为 29.4%,特异性为 100%。RAT 的阳性率与较低的循环阈值(Ct)值高度相关(P<0.0001)。RAT 的高特异性允许快速识别流感病例。然而,由于观察到的灵敏度限制,阴性结果应通过 rRT-PCR 检测进行验证。