Bilkhu Paramdeep S, Naroo Shehzad A, Wolffsohn James S
*BSc †MSc, PhD, FAAO ‡MBA, PhD, FAAO Ophthalmic Research Group, School of Life and Health Sciences, Aston University, Birmingham, United Kingdom (all authors).
Optom Vis Sci. 2014 Feb;91(2):163-70. doi: 10.1097/OPX.0000000000000134.
To evaluate eyelid temperature change and short-term effects on tear film stability and lipid layer thickness in healthy patients using a commercially available warm compress (MGDRx EyeBag) for ophthalmic use.
Eyelid temperature, noninvasive tear film breakup time (NITBUT), and tear film lipid layer thickness (TFLLT) of 22 healthy subjects were measured at baseline, immediately after, and 10 minutes after application of a heated eyebag for 5 minutes to one eye selected at random. A nonheated eyebag was applied to the contralateral eye as a control.
Eyelid temperatures, NITBUT, and TFLLT increased significantly from baseline in test eyes immediately after removal of the heated eyebag compared with those in control eyes (maximum temperature change, 2.3 ± 1.2 °C vs. 0.3 ± 0.5 °C, F = 20.533, p < 0.001; NITBUT change, 4.0 ± 2.3 seconds vs. 0.4 ± 1.7 seconds, p < 0.001; TFLLT change, 2.0 ± 0.9 grades vs. 0.1 ± 0.4 grades, Z = -4.035, p < 0.001). After 10 minutes, measurements remained significantly higher than those in controls (maximum temperature change, 1.0 ± 0.7 °C vs. 0.1 ± 0.3 °C, F = 14.247, p < 0.001; NITBUT change, 3.6 ± 2.1 seconds vs. 0.1 ± 1.9 seconds, p < 0.001; TFLLT change, 1.5 ± 0.9 vs. 0.2 ± 0.5 grades, Z = -3.835, p < 0.001). No adverse events occurred during the study.
The MGDRx EyeBag is a simple device for heating the eyelids, resulting in increased NITBUT and TFLLT in subjects without meibomian gland dysfunction that seem to be clinically significant. Future studies are required to determine clinical efficacy and evaluate safety after long-term therapy in meibomian gland dysfunction patients.
使用市售的用于眼科的热敷眼罩(MGDRx EyeBag),评估健康受试者眼睑温度变化以及对泪膜稳定性和脂质层厚度的短期影响。
对22名健康受试者,在基线时、随机选择一只眼睛使用加热眼罩5分钟后立即以及10分钟后,测量其眼睑温度、无创泪膜破裂时间(NITBUT)和泪膜脂质层厚度(TFLLT)。对侧眼睛使用未加热的眼罩作为对照。
与对照眼相比,在移除加热眼罩后,测试眼的眼睑温度、NITBUT和TFLLT较基线时显著升高(最大温度变化,2.3±1.2℃对0.3±0.5℃,F = 20.533,p < 0.001;NITBUT变化,4.0±2.3秒对0.4±1.7秒,p < 0.001;TFLLT变化,2.0±0.9级对0.1±0.4级,Z = -4.035,p < 0.001)。10分钟后,测量值仍显著高于对照眼(最大温度变化,1.0±0.7℃对0.1±0.3℃,F = 14.247,p < 0.001;NITBUT变化,3.6±2.1秒对0.1±1.9秒,p < 0.001;TFLLT变化,1.5±0.9对0.2±0.5级,Z = -3.835,p < 0.001)。研究期间未发生不良事件。
MGDRx EyeBag是一种用于加热眼睑的简单装置,可使无睑板腺功能障碍的受试者的NITBUT和TFLLT增加,这似乎具有临床意义。未来需要进行研究以确定临床疗效并评估睑板腺功能障碍患者长期治疗后的安全性。