Suppr超能文献

中空纤维透析传感器体内铬的测定。

Assay of In Vivo Chromium with a Hollow-fiber Dialysis Sensor.

机构信息

Biosensor Research Institute in Seoul National University of Technology, Seoul 139-743.

出版信息

Toxicol Res. 2010 Sep;26(3):233-6. doi: 10.5487/TR.2010.26.3.233.

Abstract

The analytical in vivo chromium ion was searched for using a voltammetric hollow-fiber dialysis sensor via square wave stripping voltammetry (SW) , cyclic voltammetry (CV) , and chronoamperometry. Under optimum parameters, the analytical results indicated linear working ranges of 50400 mg/l CV and 1080 μg/l SW within a 30-sec accumulation time. The analytical detection limit (S/N) was 6.0 μg/l. The developed method can be applied to in vivo tissues and in ex vivo toxicity assay, as well as to other materials that require chromium analysis.

摘要

采用方波 stripping 伏安法(SW)、循环伏安法(CV)和计时安培法,通过伏安式中空纤维透析传感器对体内分析铬离子进行了搜索。在最佳参数下,分析结果表明,在 30 秒的积累时间内,CV 的线性工作范围为 50400mg/L,SW 的线性工作范围为 1080μg/L。分析检测限(S/N)为 6.0μg/L。所开发的方法可应用于体内组织和体外毒性测定,以及其他需要铬分析的材料。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/aed3/3834480/90af720fc93d/toxicr-26-233-g001.jpg