PLoS One. 2013 Dec 6;8(12):e82427. doi: 10.1371/journal.pone.0082427. eCollection 2013.
To assess the longitudinal changes in optical quality including intraocular scattering in normal eyes and eyes with short tear breakup time (TBUT).
We prospectively examined twenty eyes of 20 healthy subjects, and age-matched twenty eyes of 20 short TBUT subjects. The modulation transfer function (MTF) cutoff frequency, the Strehl ratio, and the objective scattering index (OSI) were quantitatively assessed using an Optical Quality Analysis System. We investigated the changes in these variables measured consecutively at the initial examination, 5, and 10 seconds without blinking. We also compared these variables in eyes with short TBUT with those in normal eyes.
No significant differences in the MTF cutoff frequency, Strehl ratio, or OSI were detected over a 10-second period in normal eyes. These variables also became significantly degraded even over a 5-second period in eyes with short TBUT (p<0.01). We found significant differences in these variables at 5 and 10 seconds (p<0.05), but none immediately after the blink between normal and short TBUT eyes.
Optical quality including intraocular scattering deteriorated significantly with time in eyes with short TBUT, whereas we found significant differences over a 10-second period in normal eyes. Eyes with short TBUT showed greater deterioration in optical quality after the blink than normal eyes. The longitudinal assessment of optical quality may be effective in distinguishing eyes with short TBUT from normal eyes.
评估正常眼和泪膜破裂时间短(TBUT)眼的光学质量(包括眼内散射)的纵向变化。
我们前瞻性地检查了 20 名健康受试者的 20 只眼和 20 名 TBUT 短的年龄匹配受试者的 20 只眼。使用光学质量分析系统定量评估调制传递函数(MTF)截止频率、斯特列尔比和客观散射指数(OSI)。我们连续检查了这些变量在初始检查、5 秒和 10 秒不眨眼时的变化。我们还比较了 TBUT 短眼与正常眼的这些变量。
在正常眼中,MTF 截止频率、斯特列尔比或 OSI 在 10 秒内没有差异。在 TBUT 短的眼中,即使在 5 秒内,这些变量也显著恶化(p<0.01)。我们发现这些变量在 5 秒和 10 秒时存在显著差异(p<0.05),但在正常和 TBUT 短眼之间,眨眼后立即没有差异。
TBUT 短的眼中的光学质量包括眼内散射随时间显著恶化,而在正常眼中,我们发现 10 秒内存在显著差异。TBUT 短的眼在眨眼后光学质量的恶化程度大于正常眼。光学质量的纵向评估可能有助于区分 TBUT 短的眼和正常眼。