Abstract

PURPOSE

To use swept-source optical coherence tomography (OCT) to image the posterior sclera at the posterior pole and around the optic nerve head (ONH) and measure the subfoveal scleral thickness and laminar thickness to evaluate the relationship between the measured thicknesses and ocular parameters.

DESIGN

Prospective, cross-sectional design.

METHODS

The study included 103 patients with glaucoma and 43 controls with axial lengths more than 26 mm. Swept-source OCT images were obtained to capture the subfoveal and ONH regions. Subfoveal scleral thickness and laminar thickness were measured from obtained B-scan images. To verify the reproducibility of the measurement, intraclass correlation coefficients were calculated from selected B-scans. Scleral and laminar thicknesses in patients with normal-tension glaucoma (NTG) was compared with that in patients with primary open-angle glaucoma (POAG). A Pearson correlation was calculated to assess the relationships of scleral and laminar thicknesses with ocular parameters.

RESULTS

Posterior scleral thickness could be measured in 68.4% of patients, and laminar thickness could be measured in 88.6% by using swept-source OCT. Interobserver and intraobserver measurement reproducibility was moderate to excellent. The subfoveal scleral thickness was 670.84 ± 160.60 μm in the POAG group and 496.55 ± 115.20 μm in the NTG group; a significant difference between the groups was observed. Subfoveal scleral thickness (r = -0.677, P < 0.001) was negatively correlated with axial length only in patients with NTG, not in patients with POAG.

CONCLUSIONS

Swept-source OCT detected differences in the thicknesses of the posterior sclera between eyes with NTG and eyes with POAG. Subfoveal scleral thickness was negatively correlated with axial length only in eyes with NTG.

摘要

目的

使用扫频源光学相干断层扫描(OCT)对后极部和视神经头(ONH)周围的后巩膜进行成像,并测量黄斑下巩膜厚度和板层厚度,以评估所测厚度与眼部参数的关系。

设计

前瞻性、横断面设计。

方法

本研究纳入了 103 例青光眼患者和 43 例眼轴长度大于 26mm 的对照组。使用扫频源 OCT 图像获取黄斑下和 ONH 区域的图像。从获得的 B 扫描图像中测量黄斑下巩膜厚度和板层厚度。为了验证测量的可重复性,从选定的 B 扫描图像中计算了组内相关系数。将正常眼压性青光眼(NTG)患者的巩膜和板层厚度与原发性开角型青光眼(POAG)患者的巩膜和板层厚度进行比较。计算 Pearson 相关系数以评估巩膜和板层厚度与眼部参数的关系。

结果

68.4%的患者可测量后巩膜厚度,88.6%的患者可测量板层厚度。观察者间和观察者内的测量重复性为中度至极好。POAG 组的黄斑下巩膜厚度为 670.84±160.60μm,NTG 组为 496.55±115.20μm,两组间存在显著差异。仅在 NTG 患者中,黄斑下巩膜厚度(r=-0.677,P<0.001)与眼轴长度呈负相关,而在 POAG 患者中则无相关性。

结论

扫频源 OCT 检测到 NTG 眼和 POAG 眼后巩膜厚度存在差异。仅在 NTG 眼中,黄斑下巩膜厚度与眼轴长度呈负相关。