Suppr超能文献

连续高速离心法与 LipoClear®试剂去除脂血效果的评估与比较。

The evaluation and comparison of consecutive high speed centrifugation and LipoClear® reagent for lipemia removal.

机构信息

University Department of Chemistry, University Hospital Centre "Sestre Milosrdnice", Zagreb, Croatia.

University Department of Chemistry, University Hospital Centre "Sestre Milosrdnice", Zagreb, Croatia.

出版信息

Clin Biochem. 2014 Mar;47(4-5):309-14. doi: 10.1016/j.clinbiochem.2014.01.001. Epub 2014 Jan 14.

Abstract

BACKGROUND

The aim of this study was to evaluate and compare the efficiency of high speed centrifugation and LipoClear® reagent for lipemia removal in plasma samples spiked with Intralipid®, for 26 biochemistry analytes.

MATERIALS AND METHODS

A plasma pool was collected. Aliquots of the pool were spiked with Intralipid® (final concentrations of 300mg/dL and 500mg/dL Intralipid®). The lipemia was removed from the aliquots by high speed centrifugation or LipoClear® reagent. 26 analytes were determined in native, lipemic plasma and in samples after lipemia removal. The bias from the concentration in the native sample was calculated for each parameter for Intralipid® concentrations, 300 and 500mg/dL of Intralipid®, respectively. Also, the recovery for each parameter after processing the samples using high speed centrifugation and LipoClear® was calculated. The biases and test recoveries were compared with the desirable specification for imprecision (DSI) according to Ricos available at the Wesgard's website. The bias and recovery for procalcitonin were compared with DSI according to Barassi and colleagues.

RESULTS

The bias of the spiked samples exceeded the DSI at 300mg/L Intralipid® for creatinine, glucose, total protein, iron and albumin; and for all previously mentioned parameters including CK-MB, sodium, potassium, chlorides, magnesium and ALP at concentration of 500mg/L Intralipid®. For the test recovery the DSI criteria were not met for calcium, total protein, sodium and chlorides after high speed centrifugation and for glucose, calcium, phosphates, magnesium, sodium, potassium, chlorides, ALP, GGT, CK-MB, total protein, albumin and troponin T after using LipoClear®.

CONCLUSIONS

LipoClear® is not suitable for lipemia removal from samples designated for glucose, sodium, potassium, chlorides, phosphates, magnesium, CK-MB, ALP, GGT, total protein, albumin, CRP and troponin T measurements. High speed centrifugation should be used for lipemia removal instead for glucose, potassium, phosphates, magnesium, CK-MB, ALP, GGT, albumin, CRP and TnT measurements.

摘要

背景

本研究旨在评估和比较高速离心和 LipoClear®试剂去除 Intralipid®后血浆样本脂血的效率,用于 26 种生化分析物。

材料与方法

收集一个血浆池。将池等分试样中加入 Intralipid®(终浓度分别为 300mg/dL 和 500mg/dL 的 Intralipid®)。用高速离心或 LipoClear®试剂从等分试样中去除脂血。在原始、脂血血浆和脂血去除后的样品中测定 26 种分析物。对于每个参数,分别计算 Intralipid®浓度(300mg/dL 和 500mg/dL 的 Intralipid®)时的浓度偏差。此外,还计算了使用高速离心和 LipoClear®处理样品后每个参数的回收率。根据 Wesgard 网站上 Ricos 提供的不精密度(DSI)理想规格,比较了偏差和测试回收率。根据 Barassi 及其同事的建议,将降钙素的偏差和回收率与 DSI 进行了比较。

结果

在 300mg/L Intralipid®时,部分样本的偏差超过了 DSI 标准,包括肌酐、葡萄糖、总蛋白、铁和白蛋白;在 500mg/L Intralipid®时,所有上述参数(包括 CK-MB、钠、钾、氯、镁和 ALP)均超过了 DSI 标准。对于测试回收率,高速离心后钙、总蛋白、钠和氯以及 LipoClear®后葡萄糖、钙、磷酸盐、镁、钠、钾、氯、ALP、GGT、CK-MB、总蛋白、白蛋白和肌钙蛋白 T 未达到 DSI 标准。

结论

LipoClear®不适合去除用于葡萄糖、钠、钾、氯、磷酸盐、镁、CK-MB、ALP、GGT、总蛋白、白蛋白、CRP 和肌钙蛋白 T 测量的样本中的脂血。对于葡萄糖、钾、磷酸盐、镁、CK-MB、ALP、GGT、白蛋白、CRP 和 TnT 测量,应使用高速离心去除脂血。