Suppr超能文献

提高骨质疏松性椎体椎弓根螺钉拔出强度的设计与技术:现状

Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status.

作者信息

Shea Thomas M, Laun Jake, Gonzalez-Blohm Sabrina A, Doulgeris James J, Lee William E, Aghayev Kamran, Vrionis Frank D

机构信息

H. Lee Moffitt Cancer Center & Research Institute, Neuro-Oncology Department, Tampa, FL 33612, USA ; Department of Chemical & Biomedical Engineering, University of South Florida, Tampa, FL 33620, USA.

Morsani College of Medicine, University of South Florida, Tampa, FL 33612, USA.

出版信息

Biomed Res Int. 2014;2014:748393. doi: 10.1155/2014/748393. Epub 2014 Mar 3.

Abstract

Osteoporosis is a medical condition affecting men and women of different age groups and populations. The compromised bone quality caused by this disease represents an important challenge when a surgical procedure (e.g., spinal fusion) is needed after failure of conservative treatments. Different pedicle screw designs and instrumentation techniques have been explored to enhance spinal device fixation in bone of compromised quality. These include alterations of screw thread design, optimization of pilot hole size for non-self-tapping screws, modification of the implant's trajectory, and bone cement augmentation. While the true benefits and limitations of any procedure may not be realized until they are observed in a clinical setting, axial pullout tests, due in large part to their reproducibility and ease of execution, are commonly used to estimate the device's effectiveness by quantifying the change in force required to remove the screw from the body. The objective of this investigation is to provide an overview of the different pedicle screw designs and the associated surgical techniques either currently utilized or proposed to improve pullout strength in osteoporotic patients. Mechanical comparisons as well as potential advantages and disadvantages of each consideration are provided herein.

摘要

骨质疏松症是一种影响不同年龄组和人群中男性和女性的病症。当保守治疗失败后需要进行外科手术(例如脊柱融合术)时,这种疾病导致的骨质受损是一个重大挑战。人们已经探索了不同的椎弓根螺钉设计和器械技术,以增强在骨质受损的骨骼中脊柱器械的固定。这些措施包括改变螺纹设计、优化非自攻螺钉的导向孔尺寸、改变植入物的轨迹以及骨水泥强化。虽然任何手术的真正益处和局限性在临床环境中观察到之前可能无法实现,但轴向拔出试验由于在很大程度上具有可重复性且易于实施,通常用于通过量化将螺钉从体内拔出所需力的变化来评估器械的有效性。本研究的目的是概述目前使用的或为提高骨质疏松症患者的拔出强度而提出的不同椎弓根螺钉设计及相关手术技术。本文还提供了力学比较以及每种考量的潜在优缺点。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d572/3958762/33d2ec5c3d32/BMRI2014-748393.001.jpg

相似文献

2
Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength.
Spine (Phila Pa 1976). 2007 May 1;32(10):1077-83. doi: 10.1097/01.brs.0000261566.38422.40.
4
Assessment of different screw augmentation techniques and screw designs in osteoporotic spines.
Eur Spine J. 2008 Nov;17(11):1462-9. doi: 10.1007/s00586-008-0769-8. Epub 2008 Sep 10.
8
Biomechanical study of pedicle screw fixation in severely osteoporotic bone.
Spine J. 2004 Jul-Aug;4(4):402-8. doi: 10.1016/j.spinee.2003.11.010.
9
Biomechanical analysis of pedicle screw thread differential design in an osteoporotic cadaver model.
Clin Biomech (Bristol). 2012 Mar;27(3):234-40. doi: 10.1016/j.clinbiomech.2011.10.004. Epub 2011 Nov 8.

引用本文的文献

1
Factors that influence long term instrumentation stability in patients with unstable thoracolumbar injuries.
World J Orthop. 2025 Aug 18;16(8):108161. doi: 10.5312/wjo.v16.i8.108161.
3
Biomechanical Design and Validation of a Novel Elliptical Sleeve Pedicle Screw for Enhanced Spinal Fixation Stability.
Bioengineering (Basel). 2025 Jun 18;12(6):668. doi: 10.3390/bioengineering12060668.
5
Fixation Failure in Osteoporotic Bone: A Review of Complications and Outcomes.
Indian J Orthop. 2024 Dec 21;59(3):389-404. doi: 10.1007/s43465-024-01316-y. eCollection 2025 Mar.
8
Development and validation of deep learning models for identifying the brand of pedicle screws on plain spine radiographs.
JOR Spine. 2024 Sep 17;7(3):e70001. doi: 10.1002/jsp2.70001. eCollection 2024 Sep.
9
Satisfactory 2-year outcome of minimal invasive hybrid stabilization with double treated screws for unstable osteoporotic spinal fractures.
Eur J Trauma Emerg Surg. 2024 Oct;50(5):2385-2398. doi: 10.1007/s00068-024-02645-1. Epub 2024 Aug 30.

本文引用的文献

1
Calcium Triglyceride Versus Polymethylmethacrylate Augmentation: A Biomechanical Analysis of Pullout Strength.
Spine Deform. 2013 Jan;1(1):10-15. doi: 10.1016/j.jspd.2012.07.004. Epub 2013 Jan 3.
3
Premenopausal osteoporosis.
Indian J Endocrinol Metab. 2013 Mar;17(2):240-4. doi: 10.4103/2230-8210.109681.
4
Comparative analysis of posterior fusion constructs as treatments for middle and posterior column injuries: an in vitro biomechanical investigation.
Clin Biomech (Bristol). 2013 Jun;28(5):483-9. doi: 10.1016/j.clinbiomech.2013.05.001. Epub 2013 May 23.
6
Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection.
Spine J. 2013 Aug;13(8):957-65. doi: 10.1016/j.spinee.2013.03.012. Epub 2013 Apr 17.
7
Characteristics of immediate and fatigue strength of a dual-threaded pedicle screw in cadaveric spines.
Spine J. 2013 Aug;13(8):947-56. doi: 10.1016/j.spinee.2013.03.010. Epub 2013 Apr 17.
8
The impact of a distal expansion mechanism added to a standard pedicle screw on pullout resistance. A biomechanical study.
Spine J. 2013 May;13(5):532-41. doi: 10.1016/j.spinee.2013.01.038. Epub 2013 Feb 14.
10
Enhancing pedicle screw fixation in the aging spine with a novel bioactive bone cement: an in vitro biomechanical study.
Spine (Phila Pa 1976). 2012 Aug 1;37(17):E1030-7. doi: 10.1097/BRS.0b013e31825a676e.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验