Suppr超能文献

希腊阿尔塔州生活饮用水中军团菌属的检测

Detection of Legionella spp. from Domestic Water in the Prefecture of Arta, Greece.

作者信息

Dimitriadi Dimitra, Velonakis Emmanuel

机构信息

Department of Microbiology, National School of Public Health, 196 Alexandras Avenue, 115 21 Athens, Greece.

Department of Microbiology, National School of Public Health, 196 Alexandras Avenue, 115 21 Athens, Greece ; Central Public Health Laboratory, 34 Alexandrou Fleming, Vari, 16672 Attika, Greece.

出版信息

J Pathog. 2014;2014:407385. doi: 10.1155/2014/407385. Epub 2014 Mar 12.

Abstract

The aim of this research was the isolation of Legionella spp. from domestic water supply networks in the Prefecture of Arta. A total of 100 water samples, from 25 houses, were collected. Half of the samples concerned the cold water and half the hot water supply. Purpose was to detect colonization of the water networks with Legionella spp. >500 cfu/L by using the method of filtration (ISO 11731). Out of 100 samples, 6 samples from 3 houses were positive for Legionella spp. Legionella pneumophila serogroup 2-14 was isolated in 5 of 6 samples, whereas in the sixth sample Legionella anisa was identified. Only three of the samples had residual chloride over 0.2 mg/L, rate which is necessary for potable water, according to the Greek hygienic practice. Concerning the temperature of hot water, the mean temperature of the negative for Legionella samples was higher compared to the mean temperature of the positive for Legionella samples (49.9°C versus 45.5°C). It is estimated that there is risk of infection through the use of showers. The low concentration of chloride and the temperature, which was found within the limits favorable to developing Legionella spp. (20-45°C), provide fertile ground for proliferation of the bacteria.

摘要

本研究的目的是从阿尔塔州的家庭供水网络中分离嗜肺军团菌属。共采集了来自25所房屋的100份水样。其中一半样本为冷水,另一半为热水。目的是通过过滤法(ISO 11731)检测嗜肺军团菌属在供水管网中的定植情况,当含量>500 cfu/L时判定为阳性。在100份样本中,来自3所房屋的6份样本嗜肺军团菌属检测呈阳性。6份样本中的5份分离出嗜肺军团菌血清群2 - 14,而在第六份样本中鉴定出了嗜 anis 军团菌。根据希腊卫生规范,只有三份样本的余氯含量超过0.2 mg/L,这一含量是饮用水所必需的。关于热水温度,嗜肺军团菌检测阴性的样本平均温度高于嗜肺军团菌检测阳性的样本平均温度(49.9°C对45.5°C)。据估计,通过使用淋浴存在感染风险。低浓度的氯以及处于有利于嗜肺军团菌属生长的温度范围(20 - 45°C)内,为细菌的繁殖提供了适宜的环境。

相似文献

引用本文的文献

本文引用的文献

8
Legionella infection risk from domestic hot water.来自生活热水的军团菌感染风险。
Emerg Infect Dis. 2004 Mar;10(3):457-64. doi: 10.3201/eid1003.020707.
10
Legionnaires' disease contracted from patient homes: the coming of the third plague?从患者家中感染的军团病:第三次瘟疫要来了吗?
Eur J Clin Microbiol Infect Dis. 2002 Oct;21(10):699-705. doi: 10.1007/s10096-002-0813-2. Epub 2002 Oct 18.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验