Kara Tuncer Aysun, Unal Bayram
Department of Endodontics, Faculty of Dentistry, Bezmialem Vakıf University, Istanbul, Turkey.
Department of Electrical and Electronic Engineering, Faculty of Engineering, Fatih University, Istanbul, Turkey.
J Endod. 2014 May;40(5):613-7. doi: 10.1016/j.joen.2013.11.017. Epub 2014 Jan 7.
The aim of this study was to compare the effect of the EndoVac irrigation system (SybronEndo, Orange, CA) and conventional endodontic needle irrigation on sealer penetration into dentinal tubules.
Forty single-rooted, recently extracted human maxillary central incisors were randomly divided into 2 groups according to the irrigation technique used: conventional endodontic needle irrigation and EndoVac irrigation. All teeth were instrumented using the ProFile rotary system (Dentsply Maillefer, Ballaigues, Switzerland) and obturated with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany) labeled with fluorescent dye. Transverse sections at 1, 3, and 5 mm from the root apex were examined using confocal laser scanning microscopy. The total percentage and maximum depth of sealer penetration were then measured.
Mann-Whitney test results showed that EndoVac irrigation resulted in a significantly higher percentage of sealer penetration than conventional irrigation at both the 1- and 3-mm levels (P < .05). However, no difference was found at the 5-mm level. The 5-mm sections in each group showed a significantly higher percentage and maximum depth of sealer penetration than did the 1- and 3-mm sections (P < .05).
The EndoVac irrigation system significantly improved the sealer penetration at the 1- to 3-mm level over that of conventional endodontic needle irrigation.
本研究的目的是比较EndoVac冲洗系统(SybronEndo公司,加利福尼亚州奥兰治)和传统牙髓针冲洗对封闭剂渗入牙本质小管的影响。
根据所使用的冲洗技术,将40颗新近拔除的单根人上颌中切牙随机分为2组:传统牙髓针冲洗组和EndoVac冲洗组。所有牙齿均使用ProFile旋转系统(登士柏迈福公司,瑞士巴拉格)进行预备,并使用标记有荧光染料的牙胶尖和AH Plus封闭剂(登士柏德瑞公司,德国康斯坦茨)进行充填。使用共聚焦激光扫描显微镜检查距根尖1、3和5毫米处的横切片。然后测量封闭剂渗入的总百分比和最大深度。
曼-惠特尼检验结果显示,在1毫米和3毫米水平,EndoVac冲洗导致封闭剂渗入的百分比显著高于传统冲洗(P < .05)。然而,在5毫米水平未发现差异。每组的5毫米切片显示封闭剂渗入的百分比和最大深度均显著高于1毫米和3毫米切片(P < .05)。
与传统牙髓针冲洗相比,EndoVac冲洗系统在1至3毫米水平显著提高了封闭剂的渗入。