National Science Laboratory, Scottish National Blood Transfusion Service, Microbiology and Components RD&I Group, Edinburgh, UK.
Vox Sang. 2014 Oct;107(3):247-53. doi: 10.1111/vox.12157. Epub 2014 May 7.
Recently, a glucose- and bicarbonate-containing additive solution termed PAS 5 demonstrated acceptable 7-day platelet storage after >95% plasma replacement with PAS on the day of collection (Day 0). In this study, we examined platelet storage in >95% PAS 5 after manual washing of Day 1 apheresis platelets in plasma collected using either the Amicus or Trima plateletpheresis devices.
Triple platelet donations in plasma were obtained from Amicus (n = 10) and Trima (n = 10) plateletpheresis devices and stored overnight before being centrifuged and manually processed into three units with the following storage media: 100% plasma, >95% PAS 5 or 65% PAS 5/35% plasma. Platelet units were sampled on Days 1, 5 and 7 of storage using a range of tests recommended by the UK guidelines.
The majority of in vitro assay results for platelets in PAS 5 were similar to results in paired 100% plasma platelets (controls). The pH of PAS 5 stored platelet units was above the UK recommended guidelines of 7·4 by Day 5. PAS 5 platelets were no more activated than controls as evidenced by comparable soluble P-selectin levels and CD62p and CD42b expression. PAS 5 platelets also exhibited adhesion and aggregation profiles higher than (Day 1) or comparable to (Days 5 and 7) controls as measured by Impact R.
The 7-day in vitro storage parameters investigated were comparable between >95% PAS 5 and 100% plasma platelets derived from both Amicus and Trima plateletpheresis devices, with the exception that lactose dehydrogenase release rate and pH were significantly higher in PAS 5 units.
最近,一种含有葡萄糖和碳酸氢盐的添加剂溶液被称为 PAS 5,在收集日(第 0 天)用 PAS 替代>95%的血浆后,其血小板保存时间超过 7 天。在这项研究中,我们研究了在使用 Amicus 或 Trima 血小板采集器采集的血浆中对第 1 天的机采血小板进行手工洗涤后,>95%的 PAS 5 中血小板的保存情况。
从 Amicus(n=10)和 Trima(n=10)血小板采集器中获得三重血小板捐赠,并在储存过夜之前进行离心,并使用以下储存介质手工处理成三个单位:100%血浆、>95%PAS 5 或 65%PAS 5/35%血浆。在储存的第 1、5 和 7 天,使用英国指南推荐的一系列测试对血小板进行采样。
PAS 5 中血小板的大多数体外检测结果与配对的 100%血浆血小板(对照)相似。PAS 5 储存血小板单位的 pH 值在第 5 天超过了英国建议的 7.4 指南。PAS 5 血小板的激活程度与对照相似,可溶性 P-选择素水平和 CD62p 和 CD42b 表达情况表明。PAS 5 血小板的粘附和聚集曲线也高于(第 1 天)或与(第 5 和第 7 天)对照相似,这是通过 Impact R 测量得出的。
在所研究的 7 天体外储存参数中,Amicus 和 Trima 血小板采集器来源的>95%PAS 5 和 100%血浆血小板之间具有可比性,除了 PAS 5 单位的乳酸脱氢酶释放率和 pH 值显著较高外。