Suppr超能文献

两种针对老年人皮肤表面形貌的体内测量方法的可靠性和有效性。

Reliability and validity of two in vivo measurements for skin surface topography in aged adults.

作者信息

Trojahn C, Schario M, Dobos G, Blume-Peytavi U, Kottner J

机构信息

Department of Dermatology and Allergy, Clinical Research Center for Hair and Skin Science, Charité-Universitätsmedizin Berlin, Berlin, Germany.

出版信息

Skin Res Technol. 2015 Feb;21(1):54-60. doi: 10.1111/srt.12156. Epub 2014 May 24.

Abstract

BACKGROUND

The non-contact optical methods phaseshift rapid in vivo measurement of skin (PRIMOS) and surface evaluation of living skin (SELS) are widely applied for measuring skin surface topography. The aims of the present study were to evaluate reliability and validity of these methods and to compare skin roughness intraindividually.

METHODS

SELS and PRIMOS measurements were performed on four skin areas of the left and right volar forearms in 12 healthy elderly subjects. Reliability and correlations were analyzed for Visioscan® and PRIMOS roughness parameters. Student's t-tests for estimating differences between contralateral volar forearm sites were applied.

RESULTS

ICC coefficients of the Visioscan® roughness estimates ranged between 0.50 and 0.95 and of the PRIMOS measurements between 0.01 and 1.00. The Visioscan® parameters SEr, SEsm, Rmax, and Rz, and the PRIMOS parameters Ra, Rz, Smax, Wt, and Sz showed most significant correlations with each other and to additional roughness parameters. Mean roughness differences between contralateral forearm skin areas ranged between 0.0 (SEsc) and 6.7 (Rmax).

CONCLUSIONS

The Visioscan® parameters SEr, Rmax, and Rz showed most reliable and valid values and were largely comparable on contralateral forearm skin sites in elderly subjects. Rmax, Rz, and Ra should be preferred for measuring skin surface topography with PRIMOS.

摘要

背景

非接触式光学方法——皮肤体内相移快速测量法(PRIMOS)和活体皮肤表面评估法(SELS)被广泛应用于测量皮肤表面形貌。本研究的目的是评估这些方法的可靠性和有效性,并对个体内的皮肤粗糙度进行比较。

方法

对12名健康老年受试者左右前臂掌侧的四个皮肤区域进行SELS和PRIMOS测量。分析了Visioscan®和PRIMOS粗糙度参数的可靠性和相关性。应用学生t检验来估计对侧前臂掌侧部位之间的差异。

结果

Visioscan®粗糙度估计值的组内相关系数(ICC)在0.50至0.95之间,PRIMOS测量值的ICC在0.01至1.00之间。Visioscan®参数SEr、SEsm、Rmax和Rz,以及PRIMOS参数Ra、Rz、Smax、Wt和Sz彼此之间以及与其他粗糙度参数显示出最显著的相关性。对侧前臂皮肤区域之间的平均粗糙度差异在0.0(SEsc)至6.7(Rmax)之间。

结论

Visioscan®参数SEr、Rmax和Rz显示出最可靠和有效的值,并且在老年受试者对侧前臂皮肤部位上基本具有可比性。使用PRIMOS测量皮肤表面形貌时,应首选Rmax、Rz和Ra。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验