Akin Hakan, Tugut Faik, Polat Zubeyde Akin
Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Cumhuriyet University, Sivas, Turkey.
J Prosthodont. 2015 Feb;24(2):152-5. doi: 10.1111/jopr.12162. Epub 2014 Jun 11.
Denture base resins have the potential to cause cytotoxicity in vivo, and the mechanical properties of resins are affected by water sorption. There is a correlation between residual monomer and water sorption. Thus, the purpose of this study was to evaluate water sorption and cytotoxicity of light-activated urethane dimethacrylate (UDMA) denture base resin compared to a conventional heat-activated polymethyl methacrylate (PMMA) resin.
Two denture base resins, heat-activated PMMA (Meliodent) and light-activated UDMA (Eclipse), were used in this study. Cytotoxicity (5 × 1 mm(2) ) and water sorption (1 × 1 mm(2) ) specimens were made following the manufacturers' instructions (n = 10). Cytotoxicity tests of denture base resins were performed according to ISO10993-5:1999, and water sorption was evaluated according to ISO 1567:1997. ANOVA tests were employed for evaluating data (α = 0.05).
There was no cytotoxic effect in either the PMMA or UDMA group. In addition, contrary to short-term water storage, a significantly lower water sorption value was shown for UDMA resins compared to PMMA resins in both 3- and 6-month storage periods (p = 0.043 and p = 0.002, respectively).
The tested denture base materials adhered to the ISO standards for both cytotoxicity and water sorption. The cytotoxicity of the light-activated UDMA resin tested was statistically similar to that of the heat-activated PMMA resin; however, the UDMA resin exhibited decreased water sorption in long-term water storage.
义齿基托树脂有在体内引起细胞毒性的可能性,并且树脂的机械性能会受到吸水性的影响。残留单体与吸水性之间存在相关性。因此,本研究的目的是评估光固化聚氨酯二甲基丙烯酸酯(UDMA)义齿基托树脂与传统热固化聚甲基丙烯酸甲酯(PMMA)树脂相比的吸水性和细胞毒性。
本研究使用了两种义齿基托树脂,热固化PMMA(Meliodent)和光固化UDMA(Eclipse)。按照制造商的说明制作细胞毒性(5×1mm²)和吸水性(1×1mm²)标本(n = 10)。义齿基托树脂的细胞毒性测试按照ISO10993 - 5:1999进行,吸水性评估按照ISO 1567:1997进行。采用方差分析测试来评估数据(α = 0.05)。
PMMA组和UDMA组均未产生细胞毒性作用。此外,与短期水储存情况相反,在3个月和6个月的储存期内,UDMA树脂的吸水性值均显著低于PMMA树脂(分别为p = 0.043和p = 0.002)。
所测试的义齿基托材料在细胞毒性和吸水性方面均符合ISO标准。所测试的光固化UDMA树脂的细胞毒性在统计学上与热固化PMMA树脂相似;然而,UDMA树脂在长期水储存中表现出吸水性降低。