Suppr超能文献

单焦点和多焦点软性隐形眼镜的屈光度分布

Power profiles of single vision and multifocal soft contact lenses.

作者信息

Wagner Sandra, Conrad Fabian, Bakaraju Ravi C, Fedtke Cathleen, Ehrmann Klaus, Holden Brien A

机构信息

Aalen University, Germany.

Brien Holden Vision Institute, Sydney, Australia.

出版信息

Cont Lens Anterior Eye. 2015 Feb;38(1):2-14. doi: 10.1016/j.clae.2014.07.008. Epub 2014 Aug 16.

Abstract

PURPOSE

The purpose of this study was to investigate the optical zone power profile of the most commonly prescribed soft contact lenses to assess their potential impact on peripheral refractive error and hence myopia progression.

METHODS

The optical power profiles of six single vision and ten multifocal contact lenses of five manufacturers in the powers -1.00 D, -3.00 D, and -6.00 D were measured using the SHSOphthalmic (Optocraft GmbH, Erlangen, Germany). Instrument repeatability was also investigated.

RESULTS

Instrument repeatability was dependent on the distance from the optical centre, manifesting unreliable data for the central 1mm of the optic zone. Single vision contact lens measurements of -6.00 D lenses revealed omafilcon A having the most negative spherical aberration, lotrafilcon A having the least. Somofilcon A had the highest minus power and lotrafilcon A the biggest deviation in positive direction, relative to their respective labelled powers. Negative spherical aberration occurred for almost all of the multifocal contact lenses, including the centre-distance designs etafilcon A bifocal and omafilcon A multifocal. Lotrafilcon B and balafilcon A seem to rely predominantly on the spherical aberration component to provide multifocality.

CONCLUSIONS

Power profiles of single vision soft contact lenses varied greatly, many having a negative spherical aberration profile that would exacerbate myopia. Some lens types and powers are affected by large intra-batch variability or power offsets of more than 0.25 dioptres. Evaluation of power profiles of multifocal lenses was derived that provides helpful information for prescribing lenses for presbyopes and progressing myopes.

摘要

目的

本研究旨在调查最常处方的软性隐形眼镜的光学区屈光力分布,以评估其对周边屈光不正的潜在影响,进而评估其对近视进展的影响。

方法

使用SHS Ophthalmic(德国埃尔兰根Optocraft GmbH公司)测量了五个制造商生产的六种单焦点和十种多焦点隐形眼镜在-1.00 D、-3.00 D和-6.00 D屈光度下的屈光力分布。还研究了仪器的重复性。

结果

仪器的重复性取决于与光学中心的距离,在光学区中心1mm处的数据不可靠。-6.00 D单焦点隐形眼镜的测量结果显示,奥马菲康A的负球差最大,洛替菲康A的负球差最小。相对于各自的标称屈光度,索莫菲康A的负屈光度最高,洛替菲康A在正方向上的偏差最大。几乎所有多焦点隐形眼镜都存在负球差,包括中距离设计的依他菲康A双焦点和奥马菲康A多焦点。洛替菲康B和巴拉菲康A似乎主要依靠球差成分来提供多焦点性。

结论

单焦点软性隐形眼镜的屈光力分布差异很大,许多具有负球差分布,这会加剧近视。一些镜片类型和屈光度受批次内较大变异性或超过0.25屈光度的屈光度偏差影响。得出了多焦点镜片屈光力分布的评估结果,为老花眼和进展性近视患者配镜提供了有用信息。