Domínguez-Vicent Alberto, Marín-Franch Iván, Esteve-Taboada Jose Juan, Madrid-Costa David, Montés-Micó Robert
Optometry Research Group (GIO), Department of Optics, University of Valencia, Spain.
Optometry Research Group (GIO), Department of Optics, University of Valencia, Spain.
Cont Lens Anterior Eye. 2015 Jun;38(3):168-72. doi: 10.1016/j.clae.2015.01.013. Epub 2015 Feb 19.
To evaluate the repeatability of an optical device (NIMO TR1504, Lambda-X, Belgium) for measuring multifocal contact lens power profiles.
The NIMO TR1504 was used to measure power profiles 30 times for each of 10 different contact lenses from 4 major companies. All contact lenses were labelled as -3D for distance vision; half were for high addition and half for low addition. The optical zone in all measurements was set to 3-mm radius. For each lens, the median power profile and the residuals of the 30 measurements were calculated. The 95% confidence bands and two indices that summarize measurement errors were calculated: the repeatability limit and an index of repeatability heterogeneity, quantifying heterogeneity of measurement errors over the optical zone.
The repeatability limit was good (from 0.04D to 0.12D), for all multifocal contact lenses. Variability of measurement errors of power profiles was quite homogeneous along the optical zone for all lenses, although for some lenses variability was slightly higher in the centre than peripherally.
The repeatability of measured power profiles obtained by the NIMO TR1504 is lower than 0.12D for the multifocal contact lenses.
评估一种用于测量多焦点隐形眼镜屈光力分布的光学设备(NIMO TR1504,比利时Lambda-X公司)的重复性。
使用NIMO TR1504对来自4家主要公司的10种不同隐形眼镜各测量30次屈光力分布。所有隐形眼镜的远视力标签均为-3D;其中一半为高附加值,一半为低附加值。所有测量中的光学区半径均设定为3毫米。对于每种镜片,计算30次测量的屈光力分布中位数和残差。计算95%置信区间以及两个总结测量误差的指标:重复性限和重复性异质性指数,该指数用于量化光学区内测量误差的异质性。
所有多焦点隐形眼镜的重复性限良好(0.04D至0.12D)。所有镜片的屈光力分布测量误差沿光学区的变异性相当均匀,不过对于某些镜片,中心的变异性略高于周边。
对于多焦点隐形眼镜,NIMO TR1504测量的屈光力分布重复性低于0.12D。