Malingappa Pandurangappa, Yarradoddappa Venkataramanappa
Department of Studies in Chemistry, Central College Campus, Bangalore University, Bangalore-560001, India.
PG-Department of Chemistry, NMKRV College for Women, Jayanagar, Bangalore-560011, India.
Anal Chem Insights. 2014 Aug 17;9:67-73. doi: 10.4137/ACI.S16890. eCollection 2014.
A new chemosensor has been used to monitor atmospheric nitrogen oxides [NO + NO2] at parts per billion (ppb) level. It is based on the catalytic reaction of nitrogen oxides with rhodamine B hydrazide (RBH) to produce a colored compound through the hydrolysis of the amide bond of the molecule. A simple colorimeter has been used to monitor atmospheric nitrogen dioxide at ppb level. The air samples were purged through a sampling cuvette containing RBH solution using peristaltic pump. The proposed method has been successfully applied to monitor the ambient nitrogen dioxide levels at traffic junction points within the city limits and the results obtained are compared with the standard Griess-Ilosvay method.
一种新型化学传感器已被用于监测十亿分之一(ppb)水平的大气氮氧化物[NO + NO₂]。它基于氮氧化物与罗丹明B酰肼(RBH)的催化反应,通过分子酰胺键的水解产生一种有色化合物。一种简单的比色计已被用于监测ppb水平的大气二氧化氮。使用蠕动泵将空气样品通过装有RBH溶液的采样比色皿进行吹扫。所提出的方法已成功应用于监测城市范围内交通交汇点的环境二氧化氮水平,并将所得结果与标准的格里斯-伊洛夫西法进行比较。