• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Bacterial contamination after use and assessment of countermeasures a dust mask facepiece].

作者信息

Hinoue Mitsuo, Simada Yuka, Ishimatsu Sumiyo, Ishidao Toru, Fueta Yukiko, Hori Hajime

机构信息

Department of Environmental Management, School of Health Sciences,University of Occupational and Environmental Health, Japan, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, Fukuoka 807-8555, Japan.

出版信息

Sangyo Eiseigaku Zasshi. 2014;56(6):237-44. doi: 10.1539/sangyoeisei.B13007. Epub 2014 Sep 9.

DOI:10.1539/sangyoeisei.B13007
PMID:25212434
Abstract

OBJECTIVE

Bacteria on the facepiece of a dust respirator were measured just after use and after 24-hours storage at a room temperature after being worn, and bacteria disinfection methods other than ethanol were examined.

METHODS

The existence of bacteria on a facepiece of a mask that had been worn for about one hour in a laboratory was investigated. In order to eliminate bacteria before use on the next day, five methods of bacteria disinfection were investigated: wiping with a facial tissue impregnated with ethanol as a control; wiping with a facial tissue wetted with tap water; wiping with a dry facial tissue after wiping with one wetted with tap water; wiping with a dry facial tissue after wiping with one wetted with distilled water; and wiping with a dry facial tissue two times. The tests were carried out using silicone rubber sheets plated with bacteria collected from human skin. The disinfection methods that were as effective as facial paper wetted with ethanol, were then assayed on the facepiece of the dust respirator.

RESULTS

Bacteria were detected on the facepiece immediately after it had been worn. Bacteria were also detected on the facepiece after it had been stored at 25°C for 24-hours after being worn. The methods of wiping with a dry facial tissue after wiping with either tap water or distilled water were almost as statistically effective as wiping with ethanol wetted facial paper. Bacteria on the facepiece were decreased by wiping with a dry facial tissue after wiping with one wetted with tap water.

DISCUSSION

Colonies of bacteria were detected on a facepiece that had been stored 24 hours after being worn, which suggests that bacteria disinfection just after a respirator has been worn should be recommended. It is very important that the water on the facepiece should be removed after wiping with a wet facial tissue.

摘要

相似文献

1
[Bacterial contamination after use and assessment of countermeasures a dust mask facepiece].
Sangyo Eiseigaku Zasshi. 2014;56(6):237-44. doi: 10.1539/sangyoeisei.B13007. Epub 2014 Sep 9.
2
[Anaerobic bacterial contamination after use and assessment of countermeasures a dust mask facepiece].[使用后防尘口罩面罩的厌氧细菌污染及对策评估]
Sangyo Eiseigaku Zasshi. 2016 Oct 7;58(5):173-178. doi: 10.1539/sangyoeisei.C15005. Epub 2016 Aug 4.
3
Surgical mask placement over N95 filtering facepiece respirators: physiological effects on healthcare workers.N95 过滤式口罩上覆盖手术口罩:对医护人员的生理影响。
Respirology. 2010 Apr;15(3):516-21. doi: 10.1111/j.1440-1843.2010.01713.x. Epub 2010 Mar 11.
4
Evaluation of Regeneration Processes for Filtering Facepiece Respirators in Terms of the Bacteria Inactivation Efficiency and Influences on Filtration Performance.评估过滤式防颗粒物呼吸器的再生过程,包括细菌灭活效率以及对过滤性能的影响。
ACS Nano. 2020 Oct 27;14(10):13161-13171. doi: 10.1021/acsnano.0c04782. Epub 2020 Oct 2.
5
Sweat rate inside a full-facepiece respirator.全面罩呼吸器内的出汗率。
Am Ind Hyg Assoc J. 1997 Dec;58(12):881-4. doi: 10.1080/15428119791012225.
6
Fitness of a gas mask for the face of a worker handling organic solvents.适用于处理有机溶剂的工人面部的防毒面具适配性。
Ind Health. 1997 Apr;35(2):294-7. doi: 10.2486/indhealth.35.294.
7
Evaluation of a new disinfection procedure for ultrasound probes using ultraviolet light.使用紫外线对超声探头进行新消毒程序的评估。
J Hosp Infect. 2007 Feb;65(2):163-8. doi: 10.1016/j.jhin.2006.10.008. Epub 2006 Dec 14.
8
Effect of surgical masks worn concurrently over N95 filtering facepiece respirators: extended service life versus increased user burden.在N95过滤式面罩呼吸器上同时佩戴外科口罩的效果:延长使用寿命与增加使用者负担
J Public Health Manag Pract. 2008 Mar-Apr;14(2):E19-26. doi: 10.1097/01.PHH.0000311904.41691.fd.
9
To dry or not to dry? An assessment of the possible degradation in efficiency of preoperative skin preparation caused by wiping skin dry.擦干还是不擦干?对擦干皮肤导致术前皮肤准备效率可能降低的评估。
Ann R Coll Surg Engl. 1993 May;75(3):181-5.
10
Can ultrasound probes and coupling gel be a source of nosocomial infection in patients undergoing sonography? An in vivo and in vitro study.超声探头和耦合剂会成为接受超声检查患者医院感染的来源吗?一项体内和体外研究。
AJR Am J Roentgenol. 1995 Jun;164(6):1521-4. doi: 10.2214/ajr.164.6.7754907.