Suppr超能文献

微计算机断层扫描与牙科计算机断层扫描在评估皮质骨形态和小梁骨微结构方面的比较。

A comparison of micro-CT and dental CT in assessing cortical bone morphology and trabecular bone microarchitecture.

作者信息

Hsu Jui-Ting, Chen Ying-Ju, Ho Jung-Ting, Huang Heng-Li, Wang Shun-Ping, Cheng Fu-Chou, Wu Jay, Tsai Ming-Tzu

机构信息

School of Dentistry, College of Medicine, China Medical University, Taichung, Taiwan.

Stem Cell Medical Research Center, Department of Medical Research, Taichung Veterans General Hospital, Taichung, Taiwan.

出版信息

PLoS One. 2014 Sep 16;9(9):e107545. doi: 10.1371/journal.pone.0107545. eCollection 2014.

Abstract

OBJECTIVE

The objective of this study was to evaluate the relationship between the trabecular bone microarchitecture and cortical bone morphology by using micro-computed tomography (micro-CT) and dental cone-beam computed tomography (dental CT).

MATERIALS AND METHODS

Sixteen femurs and eight fifth lumbar vertebrae were collected from eight male Sprague Dawley rats. Four trabecular bone microarchitecture parameters related to the fifth lumbar vertebral body (percent bone volume [BV/TV], trabecular thickness [TbTh], trabecular separation [TbSp], and trabecular number [TbN]) were calculated using micro-CT. In addition, the volumetric cancellous bone grayscale value (vCanGrayscale) of the fifth lumbar vertebral body was measured using dental CT. Furthermore, four cortical bone morphology parameters of the femoral diaphysis (total cross-sectional area [TtAr], cortical area [CtAr], cortical bone area fraction [CtAr/TtAr], and cortical thickness [CtTh]) were calculated using both micro-CT and dental CT. Pearson analysis was conducted to calculate the correlation coefficients (r) of the micro-CT and dental CT measurements. Paired-sample t tests were used to compare the differences between the measurements of the four cortical bone morphology parameters obtained using micro-CT and dental CT.

RESULTS

High correlations between the vCanGrayscale measured using dental CT and the trabecular bone microarchitecture parameters (BV/TV [r = 0.84] and TbTh [r = 0.84]) measured using micro-CT were observed. The absolute value of the four cortical bone morphology parameters may be different between the dental CT and micro-CT approaches. However, high correlations (r ranged from 0.71 to 0.90) among these four cortical bone morphology parameters measured using the two approaches were obtained.

CONCLUSION

We observed high correlations between the vCanGrayscale measured using dental CT and the trabecular bone microarchitecture parameters (BV/TV and TbTh) measured using micro-CT, in addition to high correlations between the cortical bone morphology measured using micro-CT and dental CT. Further experiments are necessary to validate the use of dental CT on human bone.

摘要

目的

本研究的目的是通过使用显微计算机断层扫描(micro-CT)和牙科锥形束计算机断层扫描(牙科CT)来评估小梁骨微结构与皮质骨形态之间的关系。

材料与方法

从八只雄性Sprague Dawley大鼠身上收集了16根股骨和8个第五腰椎。使用micro-CT计算了与第五腰椎椎体相关的四个小梁骨微结构参数(骨体积百分比[BV/TV]、小梁厚度[TbTh]、小梁间距[TbSp]和小梁数量[TbN])。此外,使用牙科CT测量了第五腰椎椎体的体积松质骨灰度值(vCanGrayscale)。此外,使用micro-CT和牙科CT计算了股骨干的四个皮质骨形态参数(总横截面积[TtAr]、皮质面积[CtAr]、皮质骨面积分数[CtAr/TtAr]和皮质厚度[CtTh])。进行Pearson分析以计算micro-CT和牙科CT测量的相关系数(r)。使用配对样本t检验来比较使用micro-CT和牙科CT获得的四个皮质骨形态参数测量值之间的差异。

结果

观察到使用牙科CT测量的vCanGrayscale与使用micro-CT测量的小梁骨微结构参数(BV/TV[r = 0.84]和TbTh[r = 0.84])之间存在高度相关性。牙科CT和micro-CT方法测量的四个皮质骨形态参数的绝对值可能不同。然而,使用这两种方法测量的这四个皮质骨形态参数之间获得了高度相关性(r范围为0.71至0.90)。

结论

我们观察到使用牙科CT测量的vCanGrayscale与使用micro-CT测量的小梁骨微结构参数(BV/TV和TbTh)之间存在高度相关性,此外,使用micro-CT和牙科CT测量的皮质骨形态之间也存在高度相关性。需要进一步的实验来验证牙科CT在人体骨骼上的应用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e114/4166457/d66fefabf9f0/pone.0107545.g001.jpg