Quantification of myocardial blood flow using non-ECG-triggered MR imaging.

作者信息

Chen David, Sharif Behzad, Dharmakumar Rohan, Thomson Louise E J, Bairey Merz C Noel, Berman Daniel S, Li Debiao

机构信息

Department of Biomedical Engineering, Northwestern University, Chicago, Illinois, USA.

Biomedical Imaging Research Institute, Department of Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California, USA.

出版信息

Magn Reson Med. 2015 Sep;74(3):765-71. doi: 10.1002/mrm.25451. Epub 2014 Sep 16.

Abstract

PURPOSE

MR myocardial perfusion imaging is dependent on reliable electrocardiogram (ECG) triggering for accurate measurement of myocardial blood flow (MBF). A non-ECG-triggered method for quantitative first-pass imaging may improve clinical feasibility in patients with poor ECG signal. The purpose of this study is to evaluate the feasibility of a non-ECG-triggered method for myocardial perfusion imaging in a single slice.

METHODS

The proposed non-ECG-triggered technique uses a saturation-recovery magnetization preparation and golden-angle radial acquisition for integrated arterial input function (AIF) measurement. Image based self-gating with a temporal resolution of 42.6 ms is used to generate a first-pass image series with consistent cardiac phase. The AIF is measured using beat-by-beat T1 estimation of the ventricular blood pool. The proposed technique was performed on 14 healthy volunteers and compared against a conventional ECG-triggered dual-bolus acquisition.

RESULTS

The proposed method produced MBF with no significant difference compared with ECG-triggered technique (mean of 0.63 ± 0.22 mL/min/g to 0.73 ± 0.21 mL/min/g).

CONCLUSION

We have developed a non-ECG-triggered perfusion imaging method with T1 based measurement of the AIF in a single slice. In this preliminary study, our results demonstrate that MBF measured using the proposed method is comparable to the conventional ECG-triggered method.

摘要

目的

磁共振心肌灌注成像依赖可靠的心电图(ECG)触发来准确测量心肌血流量(MBF)。一种用于定量首过成像的非ECG触发方法可能会提高心电图信号不佳患者的临床可行性。本研究的目的是评估在单一层面进行心肌灌注成像的非ECG触发方法的可行性。

方法

所提出的非ECG触发技术使用饱和恢复磁化准备和黄金角径向采集来测量综合动脉输入函数(AIF)。基于图像的自门控技术,时间分辨率为42.6毫秒,用于生成具有一致心动周期相位的首过图像序列。通过逐搏估计心室血池的T1来测量AIF。该技术在14名健康志愿者身上进行,并与传统的ECG触发双团注采集方法进行比较。

结果

与ECG触发技术相比,所提出的方法得出的MBF无显著差异(平均值从0.63±0.22毫升/分钟/克到0.73±0.21毫升/分钟/克)。

结论

我们开发了一种非ECG触发的灌注成像方法,在单一层面基于T1测量AIF。在这项初步研究中,我们的结果表明,使用所提出的方法测量的MBF与传统的ECG触发方法相当。

相似文献

1
Quantification of myocardial blood flow using non-ECG-triggered MR imaging.
Magn Reson Med. 2015 Sep;74(3):765-71. doi: 10.1002/mrm.25451. Epub 2014 Sep 16.
2
Quantification of myocardial blood flow using non-electrocardiogram-triggered MRI with three-slice coverage.
Magn Reson Med. 2016 May;75(5):2112-20. doi: 10.1002/mrm.25787. Epub 2015 Jun 8.
3
Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.
Magn Reson Med. 2014 Dec;72(6):1620-8. doi: 10.1002/mrm.25074. Epub 2014 Jan 17.
4
All-systolic non-ECG-gated myocardial perfusion MRI: Feasibility of multi-slice continuous first-pass imaging.
Magn Reson Med. 2015 Dec;74(6):1661-74. doi: 10.1002/mrm.25752. Epub 2015 Jun 6.
9
Interstudy repeatability of self-gated quantitative myocardial perfusion MRI.
J Magn Reson Imaging. 2016 Jun;43(6):1369-78. doi: 10.1002/jmri.25107. Epub 2015 Dec 13.
10
Quantification of myocardial perfusion with self-gated cardiovascular magnetic resonance.
J Cardiovasc Magn Reson. 2015 Feb 12;17(1):14. doi: 10.1186/s12968-015-0109-1.

引用本文的文献

2
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging.
Nat Biomed Eng. 2018 Apr;2(4):215-226. doi: 10.1038/s41551-018-0217-y. Epub 2018 Apr 9.
4
Interstudy repeatability of self-gated quantitative myocardial perfusion MRI.
J Magn Reson Imaging. 2016 Jun;43(6):1369-78. doi: 10.1002/jmri.25107. Epub 2015 Dec 13.
6
Quantification of myocardial blood flow using non-electrocardiogram-triggered MRI with three-slice coverage.
Magn Reson Med. 2016 May;75(5):2112-20. doi: 10.1002/mrm.25787. Epub 2015 Jun 8.
7
Quantification of myocardial perfusion with self-gated cardiovascular magnetic resonance.
J Cardiovasc Magn Reson. 2015 Feb 12;17(1):14. doi: 10.1186/s12968-015-0109-1.

本文引用的文献

1
Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.
Magn Reson Med. 2014 Dec;72(6):1620-8. doi: 10.1002/mrm.25074. Epub 2014 Jan 17.
2
Evaluation of highly accelerated real-time cardiac cine MRI in tachycardia.
NMR Biomed. 2014 Feb;27(2):175-82. doi: 10.1002/nbm.3049. Epub 2013 Nov 21.
3
Improved quantification of myocardial blood flow using highly constrained back projection reconstruction.
Magn Reson Med. 2014 Sep;72(3):749-55. doi: 10.1002/mrm.24958. Epub 2013 Oct 1.
4
Rapid ungated myocardial perfusion cardiovascular magnetic resonance: preliminary diagnostic accuracy.
J Cardiovasc Magn Reson. 2013 Mar 27;15(1):26. doi: 10.1186/1532-429X-15-26.
7
Myocardial perfusion acquisition without magnetization preparation or gating.
Magn Reson Med. 2012 Mar;67(3):609-13. doi: 10.1002/mrm.23318. Epub 2011 Dec 21.
9
Estimates of systolic and diastolic myocardial blood flow by dynamic contrast-enhanced MRI.
Magn Reson Med. 2010 Dec;64(6):1696-703. doi: 10.1002/mrm.22538. Epub 2010 Oct 6.
10

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验