Suppr超能文献

双模式人工耳蜗使用者的音调适应模式:随时间变化及积累经验后

Pitch adaptation patterns in bimodal cochlear implant users: over time and after experience.

作者信息

Reiss Lina A J, Ito Rindy A, Eggleston Jessica L, Liao Selena, Becker Jillian J, Lakin Carrie E, Warren Frank M, McMenomey Sean O

机构信息

Department of Otolaryngology, Oregon Health and Science University, Portland, Oregon, USA.

出版信息

Ear Hear. 2015 Mar-Apr;36(2):e23-34. doi: 10.1097/AUD.0000000000000114.

Abstract

OBJECTIVES

Pitch plasticity has been observed in Hybrid cochlear implant (CI) users. Does pitch plasticity also occur in bimodal CI users with traditional long-electrode CIs, and is pitch adaptation pattern associated with electrode discrimination or speech recognition performance? The goals of this study were to characterize pitch adaptation patterns in long-electrode CI users, to correlate these patterns with electrode discrimination and speech perception outcomes, and to analyze which subject factors are associated with the different patterns.

DESIGN

Electric-to-acoustic pitch matches were obtained in 19 subjects over time from CI activation to at least 12 months after activation, and in a separate group of 18 subjects in a single visit after at least 24 months of CI experience. Audiometric thresholds, electrode discrimination performance, and speech perception scores were also measured.

RESULTS

Subjects measured over time had pitch adaptation patterns that fit one of the following categories: (1) "Pitch-adapting," that is, the mismatch between perceived electrode pitch and the corresponding frequency-to-electrode allocations decreased; (2) "Pitch-dropping," that is, the pitches of multiple electrodes dropped and converged to a similar low-pitch; and (3) "Pitch-unchanging," that is, the electrode pitches did not change. Subjects measured after CI experience had a parallel set of adaptation patterns: (1) "Matched-pitch," that is, the electrode pitch was matched to the frequency allocation; (2) "Low-pitch," that is, the pitches of multiple electrodes were all around the lowest frequency allocation; and (3) "Nonmatched-pitch," that is, the pitch patterns were compressed relative to the frequency allocations and did not fit either the matched-pitch or low-pitch categories. Unlike Hybrid CI users which were mostly in the pitch-adapting or matched-pitch category, the majority of bimodal CI users were in the latter two categories, pitch-dropping/low-pitch or pitch-unchanging/nonmatched-pitch. Subjects with pitch-adapting or matched-pitch patterns tended to have better low-frequency thresholds than subjects in the latter categories. Changes in electrode discrimination over time were not associated with changes in pitch differences between electrodes. Reductions in speech perception scores over time showed a weak but nonsignificant association with dropping-pitch patterns.

CONCLUSIONS

Bimodal CI users with more residual hearing may have somewhat greater similarity to Hybrid CI users and be more likely to adapt pitch perception to reduce mismatch with the frequencies allocated to the electrodes and the acoustic hearing. In contrast, bimodal CI users with less residual hearing exhibit either no adaptation, or surprisingly, a third pattern in which the pitches of the basal electrodes drop to match the frequency range allocated to the most apical electrode. The lack of association of electrode discrimination changes with pitch changes suggests that electrode discrimination does not depend on perceived pitch differences between electrodes, but rather on some other characteristics such as timbre. In contrast, speech perception may depend more on pitch perception and the ability to distinguish pitch between electrodes, especially since during multielectrode stimulation, cues such as timbre may be less useful for discrimination.

摘要

目的

在混合式人工耳蜗(CI)使用者中观察到了音调可塑性。在使用传统长电极CI的双耳CI使用者中是否也会出现音调可塑性,以及音调适应模式是否与电极辨别或言语识别表现相关?本研究的目的是描述长电极CI使用者的音调适应模式,将这些模式与电极辨别和言语感知结果相关联,并分析哪些受试者因素与不同模式相关。

设计

在19名受试者中,从CI激活开始到激活后至少12个月,随时间获取电声音调匹配数据;在另一组18名受试者中,在CI使用至少24个月后的单次就诊中获取数据。还测量了听力阈值、电极辨别表现和言语感知分数。

结果

随时间测量的受试者具有符合以下类别之一的音调适应模式:(1)“音调适应型”,即感知到的电极音调与相应的频率 - 电极分配之间的不匹配减少;(2)“音调下降型”,即多个电极的音调下降并收敛到相似的低音调;(3)“音调不变型”,即电极音调不变。在有CI使用经验后测量的受试者有一组平行的适应模式:(1)“匹配音调型”,即电极音调与频率分配相匹配;(2)“低音调型”,即多个电极的音调都在最低频率分配附近;(3)“不匹配音调型”,即音调模式相对于频率分配被压缩,不符合匹配音调型或低音调型类别。与大多处于音调适应型或匹配音调型的混合式CI使用者不同,大多数双耳CI使用者处于后两类,即音调下降/低音调型或音调不变/不匹配音调型。具有音调适应型或匹配音调型模式的受试者往往比后两类受试者有更好的低频阈值。电极辨别随时间的变化与电极间音调差异的变化无关。言语感知分数随时间的降低与音调下降模式呈微弱但不显著的关联。

结论

有更多残余听力的双耳CI使用者可能与混合式CI使用者有更大的相似性,并且更有可能适应音调感知以减少与分配给电极的频率和声学听力之间的不匹配。相比之下,残余听力较少的双耳CI使用者要么没有适应,要么令人惊讶地出现第三种模式,即基底电极的音调下降以匹配分配给最顶端电极的频率范围。电极辨别变化与音调变化缺乏关联表明,电极辨别不取决于电极间感知到的音调差异,而是取决于其他一些特征,如音色。相比之下,言语感知可能更多地取决于音调感知和区分电极间音调的能力,特别是因为在多电极刺激期间,音色等线索对于辨别可能不太有用。

相似文献

引用本文的文献

3
Cognitive Functions and Subjective Hearing in Cochlear Implant Users.人工耳蜗使用者的认知功能与主观听力
J Audiol Otol. 2024 Jul;28(3):176-185. doi: 10.7874/jao.2023.00276. Epub 2024 Apr 30.

本文引用的文献

1
Abnormal binaural spectral integration in cochlear implant users.人工耳蜗使用者的双耳频谱整合异常。
J Assoc Res Otolaryngol. 2014 Apr;15(2):235-48. doi: 10.1007/s10162-013-0434-8. Epub 2014 Jan 24.
4
Development and validation of the AzBio sentence lists.发展和验证 AzBio 句子列表。
Ear Hear. 2012 Jan-Feb;33(1):112-7. doi: 10.1097/AUD.0b013e31822c2549.
9
Electro-acoustic stimulation. Acoustic and electric pitch comparisons.电声刺激。声学和电音高比较。
Audiol Neurootol. 2009;14 Suppl 1:2-7. doi: 10.1159/000206489. Epub 2009 Apr 22.