A clinical study relating CIELCH coordinates to the color dimensions of the 3D-Master System in a Spanish population.

作者信息

Gómez-Polo Cristina, Gómez-Polo Miguel, Celemín Viñuela Alicia, Martínez Vázquez de Parga Juan Antonio

机构信息

Associate Professor, Department of Dentistry, School of Medicine, University of Salamanca, Salamanca, Spain.

Associate Professor, Department of Orofacial Prosthesis, University Complutense of Madrid, Madrid, Spain.

出版信息

J Prosthet Dent. 2015 Mar;113(3):185-90. doi: 10.1016/j.prosdent.2014.09.013. Epub 2014 Nov 25.

Abstract

STATEMENT OF PROBLEM

The 3D-Master System comprises 26 physical shade tabs and intermediate shades. Determining the relationship among all the groups of lightness, chroma, and hue of the 3D-Master System (Vita Zahnfabrik) and the L*, C*, and h* coordinates is important, because according to the manufacturer, 2 Toothguide 3D-Master shades need to be mixed in a 50:50 ratio to create an intermediate shade.

PURPOSE

The purpose of the study was to relate the lightness, chroma, and hue groups of the 3D-Master System with the polar coordinates of the CIELAB chromatic space, L*, C*, and h*, and to quantify the shades tabs and intermediate shades of the 3D-Master System according to color coordinates.

MATERIAL AND METHODS

The middle third of the facial surface of a natural maxillary central incisor was measured with an Easyshade Compact spectrophotometer (Vita Zahnfabrik) in 1361 Spanish participants aged between 16 and 89 years. Natural tooth color was recorded in the 3D-Master nomenclature and in the CIE L*, C*, and h* coordinates system. The program used for the present descriptive statistical analysis of the results was SAS 9.1.3.

RESULTS

In the L* variable, the minimum was found at 47.0 and the maximum at 91.3. In the C* variable, the minimum was found at 5.9 and the maximum at 49.8, while for h*, the minimum was 67.5 degrees and the maximum 112.0 degrees.

CONCLUSIONS

Despite the limitations of this study, the 3D-Master System was found to be arranged according to L*, C*, and h* coordinates in groups of lightness, chroma, and hue. The corresponding groups of lightness, chroma, and hue can be estimated on the basis of L*, C*, and h* coordinates.

摘要

问题陈述

3D-Master系统包含26个物理比色片和中间色。确定3D-Master系统(维他公司)所有明度、彩度和色调组之间与L*、C和h坐标的关系很重要,因为根据制造商的说法,需要将2种Toothguide 3D-Master比色片按50:50的比例混合以创建中间色。

目的

本研究的目的是将3D-Master系统的明度、彩度和色调组与CIELAB色彩空间的极坐标L*、C和h相关联,并根据颜色坐标对3D-Master系统的比色片和中间色进行量化。

材料与方法

使用Easyshade Compact分光光度计(维他公司)对1361名年龄在16至89岁之间的西班牙参与者的天然上颌中切牙面部表面的中三分之一进行测量。以3D-Master命名法和CIE L*、C和h坐标系记录天然牙齿颜色。用于本结果描述性统计分析的程序为SAS 9.1.3。

结果

在L变量中,最小值为47.0,最大值为91.3。在C变量中,最小值为5.9,最大值为49.8,而对于h*,最小值为67.5度,最大值为112.0度。

结论

尽管本研究存在局限性,但发现3D-Master系统是根据明度、彩度和色调组的L*、C和h坐标排列的。可以根据L*、C和h坐标估计相应的明度、彩度和色调组。