Suppr超能文献

肝细胞癌:关于局部区域治疗后用于纤维蛋白密封剂输注的双腔导管套件的临床前数据。

Hepatocellular carcinoma: preclinical data on a dual-lumen catheter kit for fibrin sealant infusion following loco-regional treatments.

作者信息

Izzo Francesco, Albino Vittorio, Palaia Raffaele, Piccirillo Mauro, Tatangelo Fabiana, Granata Vincenza, Petrillo Antonella, Lastoria Secondo

机构信息

Istituto Nazionale per lo Studio e la Cura dei Tumori di Napoli, Fondazione "G. Pascale", Via M.Semmola, 80131 Naples, Italy.

出版信息

Infect Agent Cancer. 2014 Nov 24;9(1):39. doi: 10.1186/1750-9378-9-39. eCollection 2014.

Abstract

BACKGROUND

Fibrin sealants are currently used in a variety of surgical and endoscopic settings to improve time to haemostasis, reduce blood loss and complications. However, the application of sealants (composed of two essential components: fibrinogen and thrombin) is not without difficulties. These sealants are normally applied to the resected area using dual-chamber delivery systems. Administration of these substances with different viscosities and diverse flow rates through a long catheter means that a certain amount of force needs to be applied and clot formation and clogging at the distal end of the catheter can occur.

METHODS

We designed a novel dual-lumen catheter to facilitate the optimal application of fibrin sealant after diagnostic and therapeutic percutaneous procedures and assessed the efficacy and tolerability of this dual-lumen kit when used in a model of hepatic fine needle aspiration (FNA) biopsy and radiofrequency ablation (RFA) in an in vivo, preclinical porcine study.

RESULTS

The experimental was performed on nine pigs (mean body weight 85 ± 7 kg) and with the exception of one pig, all animals survived in good conditions until the day of hepatectomy and euthanasia. The premature death of this animal was in the veterinarian's judgment caused by a common, non-infective disease. In all nine pigs, bleeding was stopped within 3 minutes of the application of the fibrin sealant and no cases of recurrent bleeding occurred.

CONCLUSIONS

The new dual aspect catheter increased ease of delivery of the sealant and FNA liver biopsy and RFA procedures were successfully and safely performed.

摘要

背景

纤维蛋白密封剂目前用于各种外科手术和内窥镜检查中,以缩短止血时间、减少失血和并发症。然而,密封剂(由两个基本成分:纤维蛋白原和凝血酶组成)的应用并非没有困难。这些密封剂通常使用双腔输送系统应用于切除区域。通过长导管输送这些具有不同粘度和不同流速的物质意味着需要施加一定的力,并且可能会在导管远端形成凝块并堵塞。

方法

我们设计了一种新型双腔导管,以促进在诊断和治疗性经皮手术后纤维蛋白密封剂的最佳应用,并在体内临床前猪研究中,评估了这种双腔套件在肝细针穿刺活检(FNA)和射频消融(RFA)模型中使用时的疗效和耐受性。

结果

对9头猪(平均体重85±7千克)进行了实验,除1头猪外,所有动物在肝切除和安乐死之日前均状况良好地存活。兽医判断这头动物的过早死亡是由一种常见的非感染性疾病引起的。在所有9头猪中,应用纤维蛋白密封剂后3分钟内出血停止,未发生复发出血病例。

结论

新型双腔导管提高了密封剂的输送便利性,并且成功、安全地进行了FNA肝活检和RFA手术。