Suppr超能文献

Microhardness evaluation of enamel adjacent to an improved GIC sealant after different enamel pre-treatment procedures.

作者信息

Haznedaroglu E, Sozkes S, Mentes A R

机构信息

Department of Pediatric Dentistry, Dentistry Faculty, Marmara University, Turkey.

Department of Biomaterials, Biomedical Engineering, Namik Kemal University, Turkey.

出版信息

Eur J Paediatr Dent. 2014 Dec;15(4):397-400.

Abstract

AIM

This in vitro study was carried out to evaluate the microhardness of enamel adjacent to a glass ionomer cement (GIC) with high fluoride content used as a sealant (Fuji Triage, GC Corp., Japan) after laser, bur or air abrasion treatment procedures.

STUDY DESIGN

200 freshly extracted non-carious human molars were divided into 10 experimental groups according to the enamel pre-treatment method: A air abrasion (Mach 4.1 Kreativ Inc., USA); AP, Air abrasion + conditioning with 20% polyacrylic acid (GC cavity conditioner); L, Er,Cr:YSGG laser application (Waterlase, Biolase Technology, Inc., San Clemente, USA); LP, Er,Cr:YSGG laser application and fissure conditioning; B, ameloplasty carried out with a diamond bur especially designed for preparing fissures (Komet #8833); BP, ameloplasty + fissure conditioning; P, application of 20% polyacrylic acid and all fissures sealed with GIC; C, no fissure treatment, the material was applied directly to the fissures (control); R, application of 37% orthophosphoric acid and fissures sealed with a resin-based sealant (Fissurit; Voco, Germany) (control); N, no treatment (control). Half of each group of teeth were left in artificial saliva for one month and the rest for three months. The teeth were then sectioned and microhardness was measured using a Vickers test apparatus. Kruskal-Wallis, Mann-Whitney U and Dunn's multiple comparison tests were carried out (5% significance).

RESULTS

After one month results regarding hardness at the base and lateral walls of fissures were significantly higher in groups A, AP, L, LP, B, BP, P and C than in groups R and N (p<0.01), but no difference was seen between the treatment procedures. The results after three months produced similar findings with evenly increased values for all groups.

CONCLUSION

The results of this study showed that the tested GIC with a higher fluoride content seemed to improve the enamel hardness of the fissure enamel and could be regarded as an alternative material in cases where resin sealant applications are questionable.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验