Suppr超能文献

基于波前采样技术,比较通过硅橡胶和数字化口内印模获得的全瓷冠适配性的临床评估。

Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology.

作者信息

Pradíes Guillermo, Zarauz Cristina, Valverde Arelhys, Ferreiroa Alberto, Martínez-Rus Francisco

机构信息

Department of Buccofacial Prostheses, Faculty of Dentistry, Complutense University of Madrid, Pza. Ramón y Cajal, s/n Ciudad Universitaria 28040, Madrid, Spain.

Department of Buccofacial Prostheses, Faculty of Dentistry, Complutense University of Madrid, Pza. Ramón y Cajal, s/n Ciudad Universitaria 28040, Madrid, Spain.

出版信息

J Dent. 2015 Feb;43(2):201-8. doi: 10.1016/j.jdent.2014.12.007. Epub 2014 Dec 17.

Abstract

OBJECTIVE

The aim of this study was to compare the fit of ceramic crowns fabricated from conventional silicone impressions with the fit of ceramic crowns fabricated from intraoral digital impressions.

METHODS

Twenty-five participants with 30 posterior teeth with a prosthetic demand were selected for the study. Two crowns were made for each preparation. One crown was fabricated from an intraoral digital impression system (IDI group) and the other crown was fabricated from a conventional two-step silicone impression (CI group). To replicate the interface between the crown and the preparation, each crown was cemented on its corresponding clinical preparation with ultra-flow silicone. Each crown was embedded in acrylic resin to stabilise the registered interface and then cut in 2mm thick slices in a buco-lingual orientation. The internal gap was determined as the vertical distance from the internal surface of the crown to the prepared tooth surface at four points (marginal gap, axial gap, crest gap, and occlusal fossa gap) using stereomicroscopy with a magnification of 40×. Data was analysed by using Wilcoxon signed rank test (α=0.05).

RESULTS

Internal adaptation values were significantly affected by the impression technique (p=0.001). Mean marginal gap was 76.33 ± 65.32 μm for the crowns of the IDI group and 91.46 ± 72.17 μm for the CI group.

CONCLUSION

All-ceramic crowns fabricated from intraoral digital impressions with wavefront sampling technology demonstrated better internal fit than crowns manufactured from silicone impressions.

CLINICAL SIGNIFICANCE

Impressions obtained from an intraoral digital scanner based on wavefront sampling technology can be used for manufacturing ceramic crowns in the normal clinical practice with better results than conventional impressions with elastomers.

摘要

目的

本研究旨在比较由传统硅橡胶印模制作的陶瓷冠与由口内数字印模制作的陶瓷冠的适合性。

方法

选取25名有30颗后牙且有修复需求的参与者进行研究。为每个预备牙制作两个冠。一个冠由口内数字印模系统制作(IDI组),另一个冠由传统的两步法硅橡胶印模制作(CI组)。为复制冠与预备体之间的界面,每个冠用超流硅橡胶粘结在其相应的临床预备体上。每个冠嵌入丙烯酸树脂中以稳定记录的界面,然后沿颊舌方向切成2mm厚的切片。使用放大倍数为40倍的体视显微镜在四个点(边缘间隙、轴面间隙、嵴顶间隙和咬合窝间隙)确定内部间隙,即从冠的内表面到预备牙表面的垂直距离。采用Wilcoxon符号秩检验(α = 0.05)分析数据。

结果

印模技术对内部适合性值有显著影响(p = 0.001)。IDI组冠的平均边缘间隙为76.33±65.32μm,CI组为91.46±72.17μm。

结论

采用波前采样技术的口内数字印模制作的全瓷冠比硅橡胶印模制作的冠具有更好的内部适合性。

临床意义

基于波前采样技术的口内数字扫描仪获取的印模可用于常规临床实践中制作陶瓷冠,其效果优于传统的弹性体印模。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验