Choudhari Nikhil S, Neog Aditya, Latka Supriya, Srinivasan Bhaskar
Department of Glaucoma, Jadhavbhai Nathamal Singhvi, Sankara Nethralaya, Chennai, Tamil Nadu, India ; V S T Glaucoma Centre, Dr. Kallam Anji Reddy Campus, L V Prasad Eye Institute, Hyderabad, India.
Department of Glaucoma, Jadhavbhai Nathamal Singhvi, Sankara Nethralaya, Chennai, Tamil Nadu, India.
Middle East Afr J Ophthalmol. 2015 Jan-Mar;22(1):115-6. doi: 10.4103/0974-9233.148360.
Tube exposure is a known complication of Ahmed glaucoma valve (AGV) implantation. Repair of the exposed tube is not easy. A 42-year-old monocular aphakic male had undergone retinal detachment repair with placement of an episcleral-encircling band followed by implantation of AGV. He presented to the clinic on routine review with exposure of the shunt tube. The complication was managed by placing scleral and conjunctival grafts over the exposed tube using a fibrin adhesive (Tisseel kit; Baxter AG, Vienna, Austria). The novel use of the fibrin sealant in the repair of AGV tube exposure was for better graft-integration.