• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Intraocular Pressure and Trabecular Meshwork Outflow Facility After Descemet Stripping Endothelial Keratoplasty.

作者信息

Unterlauft Jan D, Elsaesser Katharina, Grehn Franz, Geerling Gerd

机构信息

*Department of Ophthalmology, University Hospital Wuerzburg, University of Wuerzburg, Wuerzburg ‡Department of Ophthalmology, University Hospital Duesseldorf, University of Duesseldorf, Duesseldorf †Department of Ophthalmology, University Hospital Leipzig, University of Leipzig, Leipzig, Germany.J.D.U. and K.E. contributed equally.

出版信息

J Glaucoma. 2016 Mar;25(3):263-8. doi: 10.1097/IJG.0000000000000208.

DOI:10.1097/IJG.0000000000000208
PMID:25651202
Abstract

PURPOSE

Increased intraocular pressure (IOP) is a frequent complication after penetrating keratoplasty and can be due to reduced trabecular meshwork outflow facility. Descemet stripping endothelial keratoplasty (DSEK) is a lamellar technique for replacing pathologic corneal endothelium and may be associated with a lower risk of postoperative IOP rise. In a prospective clinical study we studied IOP and outflow facility before and after DSEK.

METHODS

In 23 eyes of 23 patients before, 1 day, 6 weeks, and 3, 6, and 12 months after DSEK, IOP was measured using Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT). Trabecular meshwork outflow facility (C-value) was assessed by impression tonography with the Schioetz tonometer. Central corneal thickness was measured by Haag-Streit pachymetry. Best spectacle corrected visual acuity, ocular surface fluorescein staining, and corneal sensation were also recorded.

RESULTS

Mean IOP showed a trend toward increase from preoperatively to 1 year postoperatively, which was not statistically significant (GAT: 13.5±3.3 to 15.3±4.7 mm Hg; DCT: 13.7±2.9 to 16.7±4.8 mm Hg; Schioetz: 12.4±2.8 to 15.3±2.9 mm Hg). Outflow facility increased significantly from 0.19±0.03 before to 0.29±0.05 mm/Δmm Hg/min at 1 year after DSEK (P=0.002). Best spectacle corrected visual acuity increased significantly from 0.98±0.48 to 0.36±0.17 logMAR (P=0.0004). Corneal sensitivity was unchanged and corneal staining significantly decreased from the preoperative to 1 year postoperative period (P=0.01). Mean central corneal thickness changed significantly from 650±59 to 621±73 μm (P=0.002).

CONCLUSIONS

IOP as measured by GAT, DCT, and Schioetz tends to increase during the first year after DSEK in eyes without previous glaucoma, whereas trabecular meshwork outflow facility as measured by Schioetz tonography improves. These findings are likely to be due to a progressive increase of corneal rigidity affecting transcorneal pressure measurements of both IOP and trabecular meshwork outflow facility.

摘要

相似文献

1
Intraocular Pressure and Trabecular Meshwork Outflow Facility After Descemet Stripping Endothelial Keratoplasty.
J Glaucoma. 2016 Mar;25(3):263-8. doi: 10.1097/IJG.0000000000000208.
2
Intraocular pressure measurements following Descemet stripping endothelial keratoplasty.后弹力层剥除内皮角膜移植术后的眼压测量
Am J Ophthalmol. 2008 May;145(5):780-6. doi: 10.1016/j.ajo.2008.01.010. Epub 2008 Mar 10.
3
Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty.在Descemet膜剥除内皮角膜移植术后患者中使用Goldmann眼压计、I-care pro眼压计、Tonopen XL眼压计和Schiotz眼压计测量眼压的比较。
Indian J Ophthalmol. 2017 Jul;65(7):579-583. doi: 10.4103/ijo.IJO_31_17.
4
Intraocular Pressure Measurements After Descemet Membrane Endothelial Keratoplasty.Descemet膜内皮角膜移植术后的眼压测量
J Glaucoma. 2017 Mar;26(3):258-265. doi: 10.1097/IJG.0000000000000593.
5
Ocular pulse amplitude in patients with descemet stripping endothelial keratoplasty.超声生物显微镜测量在撕囊术内皮移植术中的应用。
J Glaucoma. 2014 Mar;23(3):142-4. doi: 10.1097/IJG.0b013e31826a96cd.
6
Goldmann Applanation Tonometer Versus Ocular Response Analyzer for Measuring Intraocular Pressure After Descemet Stripping Automated Endothelial Keratoplasty.在Descemet膜剥除自动内皮角膜移植术后,使用Goldmann压平眼压计与眼反应分析仪测量眼压的比较
Cornea. 2018 Nov;37(11):1370-1375. doi: 10.1097/ICO.0000000000001660.
7
Intraocular pressure measured with Goldmann, noncontact, Schiøtz, and dynamic contour tonometry after DSEK.经 DSEK 术后,应用 Goldmann、非接触式、Schiøtz 和动态轮廓眼压计测量眼压。
Cornea. 2013 Aug;32(8):1089-93. doi: 10.1097/ICO.0b013e3182883e7a.
8
Comparison of intraocular pressure post penetrating keratoplasty vs Descemet's stripping endothelial keratoplasty.穿透性角膜移植术与后弹力层剥除内皮角膜移植术后眼压的比较
Can J Ophthalmol. 2016 Feb;51(1):19-24. doi: 10.1016/j.jcjo.2015.09.014.
9
Intraocular pressure and corneal biomechanics in Fuchs' endothelial dystrophy and after posterior lamellar keratoplasty.Fuchs 内皮营养不良和后部板层角膜移植术后的眼压和角膜生物力学。
Acta Ophthalmol. 2014 Jun;92(4):350-4. doi: 10.1111/aos.12137. Epub 2013 Apr 23.
10
Changes in Corneal Biomechanical Properties After Descemet Stripping Automated Endothelial Keratoplasty for Pseudophakic Bullous Keratopathy.人工晶状体性大泡性角膜病变行后弹力层剥除自动角膜内皮移植术后角膜生物力学特性的变化
Cornea. 2016 Jan;35(1):20-4. doi: 10.1097/ICO.0000000000000684.

引用本文的文献

1
Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty.在Descemet膜剥除内皮角膜移植术后患者中使用Goldmann眼压计、I-care pro眼压计、Tonopen XL眼压计和Schiotz眼压计测量眼压的比较。
Indian J Ophthalmol. 2017 Jul;65(7):579-583. doi: 10.4103/ijo.IJO_31_17.