Evaluation of surface alterations in different retreatment nickel-titanium files: AFM and SEM study.

作者信息

Can Sağlam Baran, Görgül Güliz

机构信息

Department of Endodontics, Faculty of Dentistry, Bülent Ecevit University, Zonguldak, Turkey.

出版信息

Microsc Res Tech. 2015 May;78(5):356-62. doi: 10.1002/jemt.22481. Epub 2015 Mar 4.

Abstract

The aim of this study was to evaluate the surface changes of nickel titanium (Ni-Ti) rotary retreatment files after three and five uses. Furthermore, the effects of 2% sodium hypochlorite and chloroform solutions and sterilization procedures on the NiTi rotary retreatment surfaces were investigated. ProTaper Retreatment files, R-endo files, and Mtwo retreatment files were used for this study. The palatinal roots of maxillary molar teeth were obturated with gutta percha and Ah26. Retreatment procedures were performed with these retreatment file systems. The surface changes of untreated NiTi rotary files that were used three and five times, immersed in NaOCl and chloroform and subjected to sterilization procedures were investigated with atomic force microscopy (AFM) and scanning electron microscopy (SEM). The RMS values, three dimensional images and SEM images at various magnifications were obtained. RMS values showed that all three NiTi rotary retreatment file systems showed significant deteriorations after three and five uses. Cracks, damages and spiral construction deteriorations were detected in the SEM images after three and five uses. Furthermore, the Mtwo 15 file was broken off after five uses. AFM data indicated that 2% NaOCl caused significant surface deteriorations on NiTi rotary files and both AFM and SEM evaluation showed that chloroform solution and sterilization procedures did not cause significant surface deteriorations. In conclusion, ProTaper retreatment, R-endo, and Mtwo retreatment files showed surface damages depending on retreatment procedures. Clinicians have to consider that retreatment files always have a tendency to break off after the third time they have been used.

摘要

本研究的目的是评估镍钛(Ni-Ti)旋转再治疗锉在使用三次和五次后的表面变化。此外,还研究了2%次氯酸钠和氯仿溶液以及灭菌程序对NiTi旋转再治疗器械表面的影响。本研究使用了ProTaper再治疗锉、R-endo锉和Mtwo再治疗锉。上颌磨牙的腭根用牙胶和Ah26进行充填。使用这些再治疗锉系统进行再治疗程序。使用原子力显微镜(AFM)和扫描电子显微镜(SEM)研究了未处理的NiTi旋转锉在使用三次和五次后、浸入NaOCl和氯仿中以及经过灭菌程序后的表面变化。获得了均方根(RMS)值、三维图像和不同放大倍数下的SEM图像。RMS值表明,所有三种NiTi旋转再治疗锉系统在使用三次和五次后均出现了显著劣化。在使用三次和五次后的SEM图像中检测到裂纹、损伤和螺旋结构劣化。此外,Mtwo 15锉在使用五次后折断。AFM数据表明,2%的NaOCl会导致NiTi旋转锉表面显著劣化,AFM和SEM评估均显示氯仿溶液和灭菌程序不会导致显著的表面劣化。总之,ProTaper再治疗锉、R-endo锉和Mtwo再治疗锉根据再治疗程序会出现表面损伤。临床医生必须考虑到,再治疗锉在第三次使用后总是有折断的倾向。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验