Suppr超能文献

即时检测乙型肝炎表面抗原快速诊断试验的准确性:一项系统评价和荟萃分析

Accuracy of Rapid Point-of-Care Diagnostic Tests for Hepatitis B Surface Antigen-A Systematic Review and Meta-analysis.

作者信息

Khuroo Mehnaaz S, Khuroo Naira S, Khuroo Mohammad S

机构信息

Government Medical College Srinagar, Kashmir, Jammu & Kashmir 190010, India.

Digestive Diseases Centre, Dr Khuroo Medical Clinic, Srinagar, Kashmir, Jammu & Kashmir 190010, India.

出版信息

J Clin Exp Hepatol. 2014 Sep;4(3):226-40. doi: 10.1016/j.jceh.2014.07.008. Epub 2014 Aug 28.

Abstract

BACKGROUND

Rapid point-of-care tests provide plausible diagnostic strategy for hepatitis B surface antigen (HBsAg) in low resource areas. However, their utility depends upon their overall performance. Our objective was to meta-analyze the diagnostic accuracy of rapid point-of-care tests for HBsAg.

METHODS

Literature search was done with the help of a metasearch engine Mettā, a query interface for retrieving articles from five leading medical databases. Studies that employed rapid point-of-care tests for detection of HBsAg and compared the results with reference test were included. Two reviewers performed quality assessment of the studies and extracted data for estimating test accuracy. Twenty-seven studies were meta-analyzed and stratified by multiple parameters.

RESULTS

Twenty-seven studies had evaluated 49 test brands and generated 76 data points. Sensitivity of individual tests varied widely and were heterogeneous (range 43.5%-99.8%); while specificity estimates were more robust and close to 100% (range 90%-100%). Overall pooled sensitivity, specificity, positive likelihood ratio (LR), negative LR and diagnostic odds ratio for all tests were 97.1% (95% CI, 96.1%-97.9%), 99.9% (CI, 99.8%-100%), 118.4 (CI, 84.7-165.5), 0.032 (CI, 0.023-0.045) and 4094.7 (CI, 2504.1-6600.8) respectively. This suggested high pooled accuracy for all studies. We found substantial heterogeneity between studies. Three factors (study location, reference standard and study score) appeared most strongly associated with test estimates and observed heterogeneity. The Determine test showed consistency in performance in studies done across developed and developing countries and the Determine and the BinaxNOW tests had significantly higher estimates than pooled estimates of remaining tests. Tests revealed analytical sensitivity of 4 IU/ml against manufacturer's claim of 0.5 IU/ml; reduced sensitivity with HBsAg mutants and poor performance in seroconversion panels.

CONCLUSIONS

Tests with better analytical sensitivity need to be developed and their feasibility and outcomes in various clinical settings need to be addressed.

摘要

背景

即时检测为资源匮乏地区的乙型肝炎表面抗原(HBsAg)检测提供了可行的诊断策略。然而,其效用取决于整体性能。我们的目的是对HBsAg即时检测的诊断准确性进行荟萃分析。

方法

借助元搜索引擎Mettā(一个用于从五个主要医学数据库检索文章的查询界面)进行文献检索。纳入采用即时检测法检测HBsAg并将结果与参考检测进行比较的研究。两名评审员对研究进行质量评估并提取数据以估计检测准确性。对27项研究进行荟萃分析并按多个参数分层。

结果

27项研究评估了49个检测品牌并产生了76个数据点。各检测的敏感性差异很大且具有异质性(范围为43.5% - 99.8%);而特异性估计更为可靠且接近100%(范围为90% - 100%)。所有检测的总体合并敏感性、特异性、阳性似然比(LR)、阴性LR和诊断比值比分别为97.1%(95%CI,96.1% - 97.9%)、99.9%(CI,99.8% - 100%)、118.4(CI,84.7 - 165.5)、0.032(CI,0.023 - 0.045)和4094.7(CI,2504.1 - 6600.8)。这表明所有研究的合并准确性较高。我们发现研究之间存在显著异质性。三个因素(研究地点、参考标准和研究评分)似乎与检测估计和观察到的异质性关联最为密切。Determine检测在发达国家和发展中国家进行的研究中表现出一致性,并且Determine和BinaxNOW检测的估计值明显高于其余检测的合并估计值。检测显示针对制造商声称的0.5 IU/ml的分析敏感性为4 IU/ml;对HBsAg突变体的敏感性降低,并且在血清转换组中表现不佳。

结论

需要开发具有更好分析敏感性的检测方法,并探讨其在各种临床环境中的可行性和结果。

相似文献

6

引用本文的文献

6
Hepatitis B Virus: Advances in Prevention, Diagnosis, and Therapy.乙型肝炎病毒:预防、诊断和治疗的新进展。
Clin Microbiol Rev. 2020 Feb 26;33(2). doi: 10.1128/CMR.00046-19. Print 2020 Mar 18.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验