Nguyen Christopher, Sharif-Afshar Ali-Reza, Fan Zhaoyang, Xie Yibin, Wilson Sidney, Bi Xiaoming, Payor Lucas, Saouaf Rola, Kim Hyung, Li Debiao
Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA.
Magn Reson Med. 2016 Feb;75(2):616-26. doi: 10.1002/mrm.25609. Epub 2015 Mar 11.
To improve spatial resolution and image quality of diffusion-weighted (DW) MRI in detecting low-risk prostate cancer (lrPC) in patients undergoing active surveillance protocol (AS-PC), we propose the application of a diffusion-prepared balanced steady-state free precession (bSSFP) technique capable of multishot acquisition.
Diffusion-prepared bSSFP was compared with single-shot DW echo planar imaging (SS-DW-EPI) at two prescribed resolutions (2.1 × 2.1 × 3.5mm(3) , 0.9 × 0.9 × 3.5 mm(3) ) in nine healthy subjects and nine AS-PC patients. Geometric distortion and susceptibility artifacts were quantitatively assessed in all subjects. In AS-PC patients, lesion detection via blinded multiparametric MRI including T1-weighted, T2-weighted, dynamic contrast-enhanced imaging, and along with either of two DW methods were evaluated against 12-point biopsy.
Geometric distortion and susceptibility artifacts were significantly less for diffusion-prepared bSSFP at both prescribed spatial resolutions than SS-DW-EPI. Apparent diffusion coefficients of healthy prostate tissue were concordant between the two DW methods at both spatial resolutions. In AS-PC patients, multiparametric MRI with diffusion-prepared bSSFP had greater sensitivity (94%, 63%), accuracy (76%, 67%), positive-predictive value (54%, 48%), negative-predictive value (97%, 82%), and area under the curve (0.80, 0.67) than with SS-DW-EPI.
The proposed diffusion-prepared technique with higher spatial resolution and improved image quality over SS-DW-EPI resulted in better multiparametric MRI detection of lrPC in AS-PC patients.
为了提高在接受主动监测方案(AS-PC)的患者中检测低风险前列腺癌(lrPC)时扩散加权(DW)MRI的空间分辨率和图像质量,我们提出应用一种能够进行多激发采集的扩散准备平衡稳态自由进动(bSSFP)技术。
在9名健康受试者和9名AS-PC患者中,于两种规定分辨率(2.1×2.1×3.5mm³,0.9×0.9×3.5mm³)下,将扩散准备bSSFP与单次激发DW回波平面成像(SS-DW-EPI)进行比较。对所有受试者进行几何畸变和磁化率伪影的定量评估。在AS-PC患者中,针对12点活检,评估通过包括T1加权、T2加权、动态对比增强成像以及两种DW方法之一的盲法多参数MRI进行病变检测的情况。
在两种规定空间分辨率下,扩散准备bSSFP的几何畸变和磁化率伪影均显著少于SS-DW-EPI。在两种空间分辨率下,两种DW方法测得的健康前列腺组织的表观扩散系数一致。在AS-PC患者中,采用扩散准备bSSFP的多参数MRI在敏感性(94%,63%)、准确性(76%,67%)、阳性预测值(54%,48%)、阴性预测值(97%,82%)以及曲线下面积(0.80,0.67)方面均优于采用SS-DW-EPI的情况。
所提出的扩散准备技术具有比SS-DW-EPI更高的空间分辨率和更好的图像质量,在AS-PC患者中能更好地通过多参数MRI检测lrPC。