Suppr超能文献

一项关于斜视中抑制测量密度的试点研究。

A pilot study examining density of suppression measurement in strabismus.

作者信息

Piano Marianne, Newsham David

机构信息

Department of Vision Sciences, Glasgow Caledonian University , Glasgow , United Kingdom and.

出版信息

Strabismus. 2015;23(1):14-21. doi: 10.3109/09273972.2014.1002621. Epub 2015 Mar 19.

Abstract

PURPOSE

Establish whether the Sbisa bar, Bagolini filter (BF) bar, and neutral density filter (NDF) bar, used to measure density of suppression, are equivalent and possess test-retest reliability. Determine whether density of suppression is altered when measurement equipment/testing conditions are changed.

METHODS

Our pilot study had 10 subjects aged ≥18 years with childhood-onset strabismus, no ocular pathologies, and no binocular vision when manifest. Density of suppression upon repeated testing, with clinic lights on/off, and using a full/reduced intensity light source, was investigated. Results were analysed for test-retest reliability, equivalence, and changes with alteration of testing conditions.

RESULTS

Test-retest reliability issues were present for the BF bar (median 6 filter change from first to final test, p = 0.021) and NDF bar (median 5 filter change from first to final test, p = 0.002). Density of suppression was unaffected by environmental illumination or fixation light intensity variations. Density of suppression measurements were higher when measured with the NDF bar (e.g. NDF bar = 1.5, medium suppression, vs BF bar = 6.5, light suppression).

CONCLUSIONS

Test-retest reliability issues may be present for the two filter bars currently still under manufacture. Changes in testing conditions do not significantly affect test results, provided the same filter bar is used consistently for testing. Further studies in children with strabismus having active amblyopia treatment would be of benefit. Despite extensive use of these tests in the UK, this is to our knowledge the first study evaluating filter bar equivalence/reliability.

摘要

目的

确定用于测量抑制密度的Sbisa棒、巴戈利尼滤光片(BF)棒和中性密度滤光片(NDF)棒是否等效且具有重测信度。确定当测量设备/测试条件改变时,抑制密度是否会改变。

方法

我们的初步研究纳入了10名年龄≥18岁、患有儿童期斜视、无眼部病变且显性斜视时无双眼视觉的受试者。研究了在诊室灯光开/关以及使用全强度/降低强度光源的情况下重复测试时的抑制密度。对结果进行了重测信度、等效性以及测试条件改变时变化情况的分析。

结果

BF棒(从首次测试到最终测试,滤光片变化中位数为6,p = 0.021)和NDF棒(从首次测试到最终测试,滤光片变化中位数为5,p = 0.002)存在重测信度问题。抑制密度不受环境照明或注视光强度变化的影响。使用NDF棒测量时抑制密度测量值更高(例如,NDF棒 = 1.5,中度抑制,而BF棒 = 6.5,轻度抑制)。

结论

目前仍在生产的两种滤光片棒可能存在重测信度问题。只要在测试中始终如一地使用相同的滤光片棒,测试条件的变化不会显著影响测试结果。对正在积极进行弱视治疗的斜视儿童进行进一步研究将是有益的。尽管这些测试在英国被广泛使用,但据我们所知,这是第一项评估滤光片棒等效性/信度的研究。