Reliability of carpal angle determinations.

作者信息

Garcia-Elias M, An K N, Amadio P C, Cooney W P, Linscheid R L

机构信息

Department of Orthopedics, Mayo Clinic/Mayo Foundation, Rochester, Minn 55905.

出版信息

J Hand Surg Am. 1989 Nov;14(6):1017-21. doi: 10.1016/s0363-5023(89)80053-x.

Abstract

The radioscaphoid, radiolunate, and radiocapitate angles of nine lateral projections of the wrist (three in flexion, three in extension, and three in neutral position) of three fresh cadaver specimens were measured. Seven orthopedic surgeons (six hand surgeons and one orthopedic surgeon) made the measurements with a standard goniometer using both the axial and tangential methods of angle determination. The overall standard deviation for all measurements was 5.2 degrees, and no significant difference in variability between axial and tangential methods was found. By comparing the same angles from different wrist positions, the amount of flexion-extension motion of the capitate, scaphoid, and lunate with respect to the radius was estimated. To assess the accuracy of such a method of carpal motion determination, a more accurate stereoradiographic method of analysis of carpal kinematics was utilized. The overall estimated error of this standard goniometric method of carpal motion determination averaged 7.4 degrees.

摘要

对三个新鲜尸体标本手腕的九个侧位投影(三个屈曲位、三个伸展位和三个中立位)的桡舟、桡月和桡头角度进行了测量。七名骨科医生(六名手外科医生和一名骨科医生)使用标准测角仪,采用轴向和切线角度测定方法进行测量。所有测量的总体标准差为5.2度,轴向和切线方法之间的变异性没有显著差异。通过比较不同手腕位置的相同角度,估计了头状骨、舟状骨和月骨相对于桡骨的屈伸运动量。为了评估这种腕骨运动测定方法的准确性,采用了一种更精确的腕骨运动学立体放射摄影分析方法。这种腕骨运动测定的标准测角方法的总体估计误差平均为7.4度。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验