Suppr超能文献

人体膝关节半月板的快速体内多组分T2成像

Rapid in vivo multicomponent T2 mapping of human knee menisci.

作者信息

Liu Fang, Samsonov Alexey, Wilson John J, Blankenbaker Donna G, Block Walter F, Kijowski Richard

机构信息

Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.

Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.

出版信息

J Magn Reson Imaging. 2015 Nov;42(5):1321-8. doi: 10.1002/jmri.24901. Epub 2015 Apr 2.

Abstract

PURPOSE

To compare multicomponent T2 parameters of menisci measured using Multicomponent Driven Equilibrium Single Pulse Observation of T1 and T2 (mcDESPOT) in asymptomatic volunteers and osteoarthritis (OA) patients with intact and torn menisci.

MATERIALS AND METHODS

The prospective study was performed with Institutional Review Board approval and with all subjects signing written informed consent. mcDESPOT was performed on the knee joint of 12 asymptomatic volunteers and 14 patients with knee OA. Single-component T2 relaxation time (T2Single ), T2 relaxation time of the fast relaxing water component (T2F ), and the slow relaxing water component (T2S ), and fraction of the fast relaxing water component (FF ) of the medial and lateral menisci were measured. Multivariate linear regression models were used to compare mcDESPOT parameters between normal menisci in asymptomatic volunteers, intact menisci in OA patients, and torn menisci in OA patients with adjustment for differences in age between subjects.

RESULTS

The mean mcDESPOT parameters for normal menisci in asymptomatic volunteers, intact menisci in OA patients, and torn menisci in OA patients were respectively 16.1 msec, 18.8 msec, and 22.7 msec for T2Single ; 9.0 msec, 10.0 msec, and 11.1 msec for T2F ; 24.4 msec, 27.7 msec, and 31.4 msec for T2S ; and 34%, 32%, 27% for FF . There were significant differences (P < 0.05) in T2Single , T2F , T2S , and FF between the three groups of menisci.

CONCLUSION

The menisci of OA patients had significantly higher T2Single , T2F , and T2S and significantly lower FF than normal menisci in asymptomatic volunteers with greater changes in multicomponent T2 parameters noted in torn than intact menisci in OA patients.

摘要

目的

比较在无症状志愿者以及半月板完整和撕裂的骨关节炎(OA)患者中,使用多组分驱动平衡单脉冲T1和T2观测法(mcDESPOT)测量的半月板多组分T2参数。

材料与方法

本前瞻性研究经机构审查委员会批准,所有受试者均签署了书面知情同意书。对12名无症状志愿者和14名膝骨关节炎患者的膝关节进行mcDESPOT检查。测量内侧和外侧半月板的单组分T2弛豫时间(T2Single)、快速弛豫水组分的T2弛豫时间(T2F)、慢速弛豫水组分的T2弛豫时间(T2S)以及快速弛豫水组分的分数(FF)。使用多变量线性回归模型比较无症状志愿者正常半月板、OA患者完整半月板和OA患者撕裂半月板之间的mcDESPOT参数,并对受试者年龄差异进行校正。

结果

无症状志愿者正常半月板、OA患者完整半月板和OA患者撕裂半月板的mcDESPOT参数平均值分别为:T2Single为16.1毫秒、18.8毫秒和22.7毫秒;T2F为9.0毫秒、10.0毫秒和11.1毫秒;T2S为24.4毫秒、27.7毫秒和31.4毫秒;FF为34%、32%、27%。三组半月板的T2Single、T2F、T2S和FF存在显著差异(P < 0.05)。

结论

与无症状志愿者的正常半月板相比,OA患者的半月板T2Single、T2F和T2S显著更高,FF显著更低,且OA患者中撕裂半月板的多组分T2参数变化比完整半月板更大。

相似文献

1
Rapid in vivo multicomponent T2 mapping of human knee menisci.人体膝关节半月板的快速体内多组分T2成像
J Magn Reson Imaging. 2015 Nov;42(5):1321-8. doi: 10.1002/jmri.24901. Epub 2015 Apr 2.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验