Suppr超能文献

双组份超短回波时间 T2*分析用于评估髌腱病患者。

Bicomponent ultrashort echo time T2* analysis for assessment of patients with patellar tendinopathy.

机构信息

Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.

Department of Orthopedics and Rehabilitation, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.

出版信息

J Magn Reson Imaging. 2017 Nov;46(5):1441-1447. doi: 10.1002/jmri.25689. Epub 2017 Mar 6.

Abstract

PURPOSE

To compare bicomponent ultrashort echo time (UTE) T2* parameters of patellar tendon between healthy volunteers and patients with patellar tendinopathy.

MATERIALS AND METHODS

This study was performed with Institutional Review Board approval and with all subjects signing informed consent. A UTE- T2* mapping sequence was performed at 3.0T on the knees of 10 healthy volunteers and in 11 patients with patellar tendinopathy. The UTE- T2* relaxation times of the fast relaxing macromolecular bound water component ( T2F) and the slow relaxing bulk water component ( T2S) and the fraction of the fast relaxing macromolecular bound water component (F ) of patellar tendon were measured in all subjects. Wilcoxon rank-sum tests were used to compare UTE- T2* parameters between healthy volunteers and patients with patellar tendinopathy.

RESULTS

Mean T2F, T2S, and F of the patellar tendon was 1.5 msec, 23.1 msec, and 79.5%, respectively, for healthy volunteers and 1.9 msec, 22.3 msec, and 75.5%, respectively, for patients with patellar tendinopathy. There were statistically significant differences between groups of subjects for T2F (P = 0.01) and F (P = 0.007) but not T2S (P = 0.10) of the patellar tendon.

CONCLUSION

Patients with patellar tendinopathy had significantly higher T2F and significantly lower F of patellar tendon than healthy volunteers, which suggests that bicomponent UTE- T2 parameters can detect changes in the composition and microstructure of degenerative tendon.

LEVEL OF EVIDENCE

1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1441-1447.

摘要

目的

比较健康志愿者与髌腱病患者髌腱的双组份超短回波时间(UTE)T2*参数。

材料与方法

本研究经机构审查委员会批准,所有受试者均签署知情同意书。在 3.0T 磁共振扫描仪上对 10 名健康志愿者和 11 名髌腱病患者的膝关节进行 UTE-T2* 图谱序列扫描。在所有受试者中测量髌腱快弛豫大分子结合水成分(T2F)、慢弛豫体相水成分(T2S)和快弛豫大分子结合水成分分数(F)的 UTE-T2弛豫时间。采用 Wilcoxon 秩和检验比较健康志愿者与髌腱病患者的 UTE-T2参数。

结果

健康志愿者的髌腱 T2F、T2S 和 F 的平均值分别为 1.5 msec、23.1 msec 和 79.5%,髌腱病患者分别为 1.9 msec、22.3 msec 和 75.5%。两组受试者的 T2F(P=0.01)和 F(P=0.007)差异有统计学意义,而 T2S(P=0.10)差异无统计学意义。

结论

与健康志愿者相比,髌腱病患者髌腱的 T2F 明显升高,F 明显降低,这提示双组份 UTE-T2参数可检测退变肌腱的成分和微观结构变化。

证据水平

1 技术功效:2 级 J. 磁共振成像 2017;46:1441-1447。

相似文献

7
Rapid in vivo multicomponent T2 mapping of human knee menisci.人体膝关节半月板的快速体内多组分T2成像
J Magn Reson Imaging. 2015 Nov;42(5):1321-8. doi: 10.1002/jmri.24901. Epub 2015 Apr 2.

引用本文的文献

本文引用的文献

3
Ultrashort echo imaging of cyclically loaded rabbit patellar tendon.周期性加载兔髌腱的超短回波成像
J Biomech. 2014 Oct 17;47(13):3428-32. doi: 10.1016/j.jbiomech.2014.08.018. Epub 2014 Sep 1.
5
UTE imaging in the musculoskeletal system.肌肉骨骼系统中的UTE成像。
J Magn Reson Imaging. 2015 Apr;41(4):870-83. doi: 10.1002/jmri.24713. Epub 2014 Jul 16.
9
Effects of repetitive freeze-thawing cycles on T2 and T2 of the Achilles tendon.重复冻融循环对跟腱 T2 和 T2 的影响。
Eur J Radiol. 2014 Feb;83(2):349-53. doi: 10.1016/j.ejrad.2013.10.014. Epub 2013 Oct 27.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验