Suydam Stephen M, Soulas Elizabeth M, Elliott Dawn M, Silbernagel Karin Gravare, Buchanan Thomas S, Cortes Daniel H
Delaware Rehabilitation Institute, University of Delaware, Newark, Delaware.
J Orthop Res. 2015 Jun;33(6):926-31. doi: 10.1002/jor.22878. Epub 2015 Apr 27.
Changes in tendon viscoelastic properties are observed after injuries and during healing as a product of altered composition and structure. Continuous Shear Wave Elastography is a new technique measuring viscoelastic properties of soft tissues using external shear waves. Tendon has not been studied with this technique, therefore, the aims of this study were to establish the range of shear and viscosity moduli in healthy Achilles tendons, determine bilateral differences of these parameters and explore correlations of viscoelasticity to plantar flexion strength and tendon area. Continuous Shear Wave Elastography was performed over the free portion of both Achilles tendons from 29 subjects. Isometric plantar flexion strength and cross sectional area were measured. The average shear and viscous moduli was 83.2 kPa and 141.0 Pa-s, respectively. No correlations existed between the shear or viscous modulus and area or strength. This indicates that viscoelastic properties can be considered novel, independent biomarkers. The shear and viscosity moduli were bilaterally equivalent (p = 0.013, 0.017) which allows determining pathologies through side-to-side deviations. The average bilateral coefficient of variation was 7.2% and 9.4% for shear and viscosity modulus, respectively. The viscoelastic properties of the Achilles tendon may provide an unbiased, non-subjective rating system of tendon recovery and optimizing treatment strategies.
肌腱损伤后及愈合过程中,其粘弹性特性会因组成和结构的改变而发生变化。连续剪切波弹性成像技术是一种利用外部剪切波测量软组织粘弹性特性的新技术。目前尚未用该技术对肌腱进行研究,因此,本研究的目的是确定健康跟腱的剪切模量和粘度模量范围,确定这些参数的双侧差异,并探讨粘弹性与跖屈力量和肌腱面积之间的相关性。对29名受试者双侧跟腱的游离部分进行连续剪切波弹性成像检查。测量等长跖屈力量和横截面积。平均剪切模量和粘度模量分别为83.2kPa和141.0Pa·s。剪切模量或粘度模量与面积或力量之间不存在相关性。这表明粘弹性特性可被视为新的独立生物标志物。双侧剪切模量和粘度模量相等(p = 0.013,0.017),这有助于通过双侧偏差确定病变情况。剪切模量和粘度模量的平均双侧变异系数分别为7.2%和9.4%。跟腱的粘弹性特性可为肌腱恢复提供一个无偏倚、非主观的评级系统,并优化治疗策略。