在(201)Tl单光子发射计算机断层心肌灌注显像中,使用基于CT的μ图通过傅里叶反投影重建进行张衰减校正方法的效用。

Usefulness of the Chang attenuation correction method with use of a CT-based μ map by FBP reconstruction in (201)Tl SPECT-MPI.

作者信息

Nakamura Yuya, Tomiguchi Seiji

机构信息

Division of Medical Technology, Kumamoto University Hospital, Kumamoto, Japan,

出版信息

Ann Nucl Med. 2015 Jun;29(5):467-73. doi: 10.1007/s12149-015-0972-8. Epub 2015 Apr 22.

Abstract

OBJECTIVE

Attenuation correction (AC) on nuclear images of non-uniform domains is generally performed by a change of the computed tomography (CT) values to μ values, which are then inserted as components into the detection probability of iterative reconstruction techniques (OS-EM Iterative AC). We established an AC technique which uses a CT μ map based on the Chang AC. Our purpose in this study was to confirm the appropriateness of the Chang AC with the OS-EM and the FBP method (OS-EM Chang AC and FBP Chang AC) by evaluating the results obtained in a phantom and clinical study for (201)Tl single-photon emission-computed tomography-myocardial perfusion imaging (SPECT-MPI).

METHODS

Myocardial phantom study and retrospective clinical study were performed. Evaluations for image quality (uniformity and contrast) and image quantitative values [accurate left ventricular (LV) volume and radioactivity] were performed for both studies.

RESULTS

FBP Chang AC showed good image uniformity and proper contrast in phantom and clinical study. Accurate LV volume and radioactivity in the myocardium were also obtained by the phantom study. On the other hand, the number of iterations influenced the image quality both in OS-EM Iterative AC and OS-EM Chang AC in the phantom study. Different numbers of iterations were necessary for obtaining good contrast ratio in each of the anterior and inferior wall, and accurate LV volume.

CONCLUSIONS

The number of iterations influences the image quality and quantitative values on OS-EM Iterative Chang AC and OS-EM Chang AC images. In addition, it is difficult to set an appropriate number of iterations for the iterative reconstruction of these images in phantom and clinical studies. Therefore, FBP Chang AC is considered to be clinically useful.

摘要

目的

对于非均匀区域的核医学图像,衰减校正(AC)通常通过将计算机断层扫描(CT)值转换为μ值来进行,然后将这些μ值作为分量插入迭代重建技术(OS-EM迭代AC)的检测概率中。我们建立了一种基于张AC的使用CTμ图的AC技术。本研究的目的是通过评估在体模和临床研究中获得的结果,来确认张AC与OS-EM以及FBP方法(OS-EM张AC和FBP张AC)在(201)Tl单光子发射计算机断层扫描心肌灌注成像(SPECT-MPI)中的适用性。

方法

进行了心肌体模研究和回顾性临床研究。对两项研究都进行了图像质量(均匀性和对比度)以及图像定量值[准确的左心室(LV)容积和放射性]的评估。

结果

FBP张AC在体模和临床研究中均显示出良好的图像均匀性和适当的对比度。体模研究还获得了心肌中准确的LV容积和放射性。另一方面,在体模研究中,迭代次数对OS-EM迭代AC和OS-EM张AC的图像质量均有影响。在前壁和下壁分别获得良好的对比度比值以及准确的LV容积需要不同的迭代次数。

结论

迭代次数会影响OS-EM迭代张AC和OS-EM张AC图像的质量和定量值。此外,在体模和临床研究中,为这些图像的迭代重建设置合适的迭代次数很困难。因此,FBP张AC被认为在临床上有用。