Suppr超能文献

TRUE Test®(Mekos试验)中的对叔丁基苯酚甲醛树脂(PTBP-FR)是否会使受试患者产生过敏反应?

Is p-tert-butylphenol-formaldehyde resin (PTBP-FR) in TRUE Test® (Mekos test) sensitizing the tested patients?

作者信息

Stenberg Berndt, Bruze Magnus, Zimerson Erik

机构信息

Department of Public Health and Clinical Medicine, Dermatology and Venereology, Umeå University, 901 85, Umeå, Sweden.

Department of Occupational and Environmental Dermatology, Skåne University Hospital, Lund University, 214 28 Malmö, Sweden.

出版信息

Contact Dermatitis. 2015 Dec;73(6):350-7. doi: 10.1111/cod.12401. Epub 2015 Apr 23.

Abstract

BACKGROUND

In a population study using TRUE Test®, we noted late reactions to p-tert-butylphenol-formaldehyde resin (PTBP-FR) in 0.5% of subjects tested.

OBJECTIVES

In order to explore possible test sensitization, differences in the contents of sensitizers within PTBP-FR in test preparations for TRUE Test® and Finn Chambers® were analysed. Subjects allergic to PTBP-FR and subjects with late reactions to PTBP-FR were retested in order to explore whether these groups reacted to different PTBP-FR sensitizers.

PATIENTS/MATERIALS/METHODS: Four individuals with late reactions and 5 subjects with established allergy to PTBP-FR were retested with defined PTBP-FR sensitizers. PTBP-FR constituents in patches from TRUE Test® were analysed with high-performance liquid chromatography. Previously analysed samples of PTBP-FR constituents served as a reference.

RESULTS

The pattern of reaction to PTBP-FR sensitizers was similar in both groups. Subjects with suspected sensitization had somewhat stronger reactions than controls. The concentrations of monomers, dimers and trimers were generally higher in the TRUE Test® resin than in reference substances.

CONCLUSIONS

Retesting did not add information regarding causes of possible sensitization. Analysis showed that the resin used in TRUE Test® has a lower degree of polymerization or condensation, which may enhance its sensitizing properties. A follow-up of late reactions to PTBP-FR in TRUE Test® should be carried out.

摘要

背景

在一项使用TRUE Test®的人群研究中,我们注意到在接受检测的受试者中有0.5%对对叔丁基苯酚甲醛树脂(PTBP - FR)出现迟发性反应。

目的

为了探究可能的检测致敏情况,分析了TRUE Test®和Finn Chambers®检测制剂中PTBP - FR内致敏剂含量的差异。对PTBP - FR过敏的受试者和对PTBP - FR有迟发性反应的受试者再次进行检测,以探究这些组是否对不同的PTBP - FR致敏剂有反应。

患者/材料/方法:对4名有迟发性反应的个体和5名已确诊对PTBP - FR过敏的受试者用特定的PTBP - FR致敏剂再次进行检测。用高效液相色谱法分析TRUE Test®贴片内的PTBP - FR成分。先前分析的PTBP - FR成分样品用作对照。

结果

两组对PTBP - FR致敏剂的反应模式相似。疑似致敏的受试者反应比对照组略强。TRUE Test®树脂中单体、二聚体和三聚体的浓度通常高于对照物质。

结论

再次检测并未提供有关可能致敏原因的信息。分析表明,TRUE Test®中使用的树脂聚合或缩合程度较低,这可能会增强其致敏特性。应对TRUE Test®中PTBP - FR的迟发性反应进行随访。

相似文献

1
Is p-tert-butylphenol-formaldehyde resin (PTBP-FR) in TRUE Test® (Mekos test) sensitizing the tested patients?
Contact Dermatitis. 2015 Dec;73(6):350-7. doi: 10.1111/cod.12401. Epub 2015 Apr 23.
4
Contact allergy to the monomers in p-tert-butylphenol-formaldehyde resin.
Contact Dermatitis. 2002 Sep;47(3):147-53. doi: 10.1034/j.1600-0536.2002.470304.x.
5
Sensitizing capacity of 5,5'-di-tert-butyl-2,2'-dihydorxy-(hydroxymethyl)-dibenzyl ethers in the guinea pig.
Contact Dermatitis. 2000 Aug;43(2):72-8. doi: 10.1034/j.1600-0536.2000.043002072.x.
6
Clinical aspects of para-tertiary-butylphenolformaldehyde resin (PTBP-FR) allergy.
Contact Dermatitis. 1989 Nov;21(5):312-5. doi: 10.1111/j.1600-0536.1989.tb04749.x.
7
Contact allergy to the monomers of p-tert-butylphenol-formaldehyde resin in the guinea pig.
Contact Dermatitis. 1998 Nov;39(5):222-6. doi: 10.1111/j.1600-0536.1998.tb05913.x.
9
Sensitizing capacity of some trimers in p-tert-butylphenol-formaldehyde resin.
Contact Dermatitis. 2002 Jul;47(1):40-6. doi: 10.1034/j.1600-0536.2002.470108.x.
10
Demonstration of the contact sensitizer p-tert-butylcatechol in p-tert-butylphenol formaldehyde resin.
Am J Contact Dermat. 1999 Mar;10(1):2-6. doi: 10.1016/s1046-199x(99)90086-6.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验