This study addresses the question of whether the neuropathological findings on the olfactory bulb (OB) in idiopathic Parkinson's disease (IPD) correspond to a detectable change in volume of the OB. Additionally, the relationship between OB volume and residual olfactory function, clinical disease characteristics and age are investigated.
Fifty-two IPD patients were investigated and compared to 31 healthy age-matched controls. All participants were scanned using a 3 T magnetic resonance imaging MRI scanner including a T2 DRIVE sequence in coronal slices through the OB. The OB volumes were measured via manual segmentation of the OB. Olfactory testing was carried out using the Sniffin' Sticks test battery.
The OB volume in the IPD group was 42.1 mm³ (SD ± 11.6) for the right and 41.5 mm³ (SD ± 11.7) for the left OB and showed no difference from the controls. Additionally, there were no significant correlations between OB volume and disease characteristics such as disease duration or Unified Parkinson's Disease Rating Scale motor score. Likewise, patients' residual smell function did not correlate with their OB volume. In contrast, controls indicated a correlation between smell function and OB volume.
The study shows that high resolution MRI does not show a detectable volume loss of the OB in PD patients. It is concluded that OB measurement using in vivo high resolution MRI at 3 T is not helpful to identify IPD.
本研究旨在探讨特发性帕金森病(IPD)患者嗅球(OB)的神经病理学发现是否与 OB 体积的可检测变化相对应。此外,还研究了 OB 体积与残余嗅觉功能、临床疾病特征和年龄之间的关系。
对 52 名 IPD 患者进行了调查,并与 31 名年龄匹配的健康对照组进行了比较。所有参与者均使用 3T 磁共振成像(MRI)扫描仪进行扫描,包括冠状切片通过 OB 的 T2 DRIVE 序列。通过手动分割 OB 来测量 OB 体积。嗅觉测试使用 Sniffin' Sticks 测试套件进行。
IPD 组右侧 OB 体积为 42.1mm³(SD±11.6),左侧 OB 体积为 41.5mm³(SD±11.7),与对照组无差异。此外,OB 体积与疾病特征(如疾病持续时间或统一帕金森病评定量表运动评分)之间无显著相关性。同样,患者的残余嗅觉功能与 OB 体积之间也没有相关性。相比之下,对照组的嗅觉功能与 OB 体积之间存在相关性。
该研究表明,高分辨率 MRI 并未显示 PD 患者 OB 有可检测到的体积损失。因此,使用 3T 体内高分辨率 MRI 测量 OB 对识别 IPD 没有帮助。