Barker B A, Ratcliffe J G, Turner G C
Med Lab Sci. 1989 Apr;46(2):97-100.
In order to develop a rapid and reliable method for screening large numbers of urines for leucocytes and bacteria a dipstick method was used with colorimetric reading of colour changes with a reflectance spectrophotometer. One thousand consecutive urine specimens were tested by that method using a single dipstick for leucocyte esterase, nitrite, blood and protein in parallel with routine methods for enumeration of leucocytes by microscopy and quantitative culture for bacteria. Results of the four dipstick tests taken together had predictive values of 83.7% for a positive test for evidence of infection and 97.2% for a negative result. The false negative rate was 1%. Of the 191 urines with a significant bacteriuria (greater than 10(5) organisms/ml), 10 were false negatives by dipstick testing, representing 5% of all infected urines. Elimination of the need for culture on specimens that were negative by all four tests would reduce the workload by 36%.
为开发一种快速可靠的方法来筛查大量尿液中的白细胞和细菌,采用了试纸条法,并用反射分光光度计比色读取颜色变化。用该方法对1000份连续尿液标本进行检测,使用单一试纸条检测白细胞酯酶、亚硝酸盐、血液和蛋白质,同时采用显微镜计数白细胞和细菌定量培养的常规方法。四项试纸条检测结果综合起来,对感染证据阳性检测的预测值为83.7%,阴性结果的预测值为97.2%。假阴性率为1%。在191份有显著菌尿(大于10⁵个菌落形成单位/毫升)的尿液中,10份经试纸条检测为假阴性,占所有感染尿液的5%。对所有四项检测均为阴性的标本无需进行培养,这将使工作量减少36%。