AIM

To determine the repeatability and agreement of stereoacuity measurements made using some of the most widely used clinical tests: Frisby, TNO, Randot and Titmus.

METHODS

Stereoacuity was measured in two different sessions separated by a time interval of at least 24h but no longer than 1wk in 74 subjects of mean age 20.6y using the four methods. The study participants were divided into two groups: subjects with normal binocular vision and subjects with abnormal binocular vision.

RESULTS

Best repeatability was shown by the Frisby and Titmus [coefficient of repeatability (COR): ±13 and ±12s arc respectively] in the subjects with normal binocular vision though a clear ceiling effect was noted. In the subjects with abnormal binocular vision, best repeatability was shown by the Frisby (COR: ±69s arc) and Randot (COR: ±72s arc). In both groups, the TNO test showed poorest agreement with the other tests.

CONCLUSION

The repeatability of stereoacuity measures was low in subjects with poor binocular vision yet fairly good in subjects with normal binocular vision with the exception of the TNO test. The reduced agreement detected between the tests indicates they cannot be used interchangeably.

摘要

目的

使用一些最常用的临床测试(Frisby、TNO、Randot和Titmus)来确定立体视锐度测量的可重复性和一致性。

方法

采用这四种方法,对平均年龄20.6岁的74名受试者在至少间隔24小时但不超过1周的两个不同时间段测量立体视锐度。研究参与者被分为两组:双眼视觉正常的受试者和双眼视觉异常的受试者。

结果

在双眼视觉正常的受试者中,Frisby和Titmus表现出最佳的可重复性[可重复性系数(COR)分别为±13和±12秒弧度],不过存在明显的上限效应。在双眼视觉异常的受试者中,Frisby(COR:±69秒弧度)和Randot(COR:±72秒弧度)表现出最佳的可重复性。在两组中,TNO测试与其他测试的一致性最差。

结论

除TNO测试外,双眼视觉不佳的受试者立体视锐度测量的可重复性较低,而双眼视觉正常的受试者的可重复性相当好。测试之间检测到的一致性降低表明它们不能互换使用。

相似文献

1
Intraexaminer repeatability and agreement in stereoacuity measurements made in young adults.
Int J Ophthalmol. 2015 Apr 18;8(2):374-81. doi: 10.3980/j.issn.2222-3959.2015.02.29. eCollection 2015.
2
3
Maximum angle of horizontal strabismus consistent with true stereopsis.
J AAPOS. 2004 Feb;8(1):28-34. doi: 10.1016/j.jaapos.2003.08.010.
4
Test retest variability in stereoacuity measurements.
Strabismus. 2023 Sep;31(3):188-196. doi: 10.1080/09273972.2023.2252853. Epub 2023 Sep 13.
5
Normative Values for Near and Distance Clinical Tests of Stereoacuity.
Strabismus. 2016 Dec;24(4):169-172. doi: 10.1080/09273972.2016.1242636.
6
Stereoacuity norms for school-age children using the Frisby stereotest.
J AAPOS. 2013 Dec;17(6):582-7. doi: 10.1016/j.jaapos.2013.08.012.
7
Monocular and binocular depth discrimination thresholds.
Optom Vis Sci. 1999 Nov;76(11):770-82. doi: 10.1097/00006324-199911000-00026.

引用本文的文献

2
Can viewing a 3D movie improve visual function in children with a history of amblyopia and neurotypical children?: A pilot study.
PLoS One. 2024 Jun 25;19(6):e0305401. doi: 10.1371/journal.pone.0305401. eCollection 2024.
3
Comparison of Foraging Interactive D-prime and Angular Indication Measurement Stereo with different methods to assess stereopsis.
PLoS One. 2024 Jun 7;19(6):e0305036. doi: 10.1371/journal.pone.0305036. eCollection 2024.
4
Linear perspective cues have a greater effect on the perceptual rescaling of distant stimuli than textures in the virtual environment.
Atten Percept Psychophys. 2024 Feb;86(2):653-665. doi: 10.3758/s13414-023-02834-x. Epub 2024 Jan 5.
5
Effects of the Loss of Binocular and Motion Parallax on Static Postural Stability.
Sensors (Basel). 2023 Apr 20;23(8):4139. doi: 10.3390/s23084139.
6
Differences in stereoacuity between crossed and uncrossed disparities reduce with practice.
Ophthalmic Physiol Opt. 2022 Nov;42(6):1353-1362. doi: 10.1111/opo.13040. Epub 2022 Aug 23.
7
The incidence of falls after first and second eye cataract surgery: a longitudinal cohort study.
Med J Aust. 2022 Jul 18;217(2):94-99. doi: 10.5694/mja2.51611. Epub 2022 Jun 15.
8
An Evaluation of the Agreement Between a Computerized Stereoscopic Game Test and the TNO Stereoacuity Test.
Clin Optom (Auckl). 2021 Jul 5;13:181-190. doi: 10.2147/OPTO.S308445. eCollection 2021.
9
Reduced macular thickness and macular vessel density in early-treated adult patients with PKU.
Mol Genet Metab Rep. 2021 May 5;27:100767. doi: 10.1016/j.ymgmr.2021.100767. eCollection 2021 Jun.
10
Evaluating the Mechanism by Which the TNO Stereo Test Overestimates Stereo Thresholds.
J Ophthalmol. 2021 Jan 18;2021:6665638. doi: 10.1155/2021/6665638. eCollection 2021.

本文引用的文献

1
Factors influencing stereoacuity levels after surgery to correct unilateral developmental cataracts in children.
Int J Ophthalmol. 2013 Jun 18;6(3):331-6. doi: 10.3980/j.issn.2222-3959.2013.03.14. Print 2013.
2
The effect of amblyopia treatment on stereoacuity.
J AAPOS. 2013 Apr;17(2):166-73. doi: 10.1016/j.jaapos.2012.10.021.
3
Clinical evaluation of stereopsis.
Vision Res. 2013 Sep 20;90:38-42. doi: 10.1016/j.visres.2012.10.005. Epub 2012 Oct 22.
4
Stability of near stereoacuity in childhood intermittent exotropia.
J AAPOS. 2011 Oct;15(5):462-7. doi: 10.1016/j.jaapos.2011.06.008.
5
The functional significance of stereopsis.
Invest Ophthalmol Vis Sci. 2010 Apr;51(4):2019-23. doi: 10.1167/iovs.09-4434. Epub 2009 Nov 20.
6
Defining real change in measures of stereoacuity.
Ophthalmology. 2009 Feb;116(2):281-5. doi: 10.1016/j.ophtha.2008.09.012. Epub 2008 Dec 16.
8
The effect of amblyopia on fine motor skills in children.
Invest Ophthalmol Vis Sci. 2008 Feb;49(2):594-603. doi: 10.1167/iovs.07-0869.
9
Neural basis for stereopsis from second-order contrast cues.
J Neurosci. 2006 Apr 19;26(16):4370-82. doi: 10.1523/JNEUROSCI.4379-05.2006.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验