亮度对视力正常个体以及轻度创伤性脑损伤/脑震荡患者视觉诱发电位的影响。

Effect of luminance on the visually-evoked potential in visually-normal individuals and in mTBI/concussion.

作者信息

Fimreite Vanessa, Ciuffreda Kenneth J, Yadav Naveen K

机构信息

a Department of Biological and Vision Sciences , SUNY/State College of Optometry , New York , NY , USA.

出版信息

Brain Inj. 2015 Sep;29(10):1199-1210. doi: 10.3109/02699052.2015.1035329. Epub 2015 Jun 17.

Abstract

PURPOSE

To assess quantitatively the effect of luminance on VEP amplitude and latency in visually-normals (VN) and patients with mild traumatic brain injury (mTBI).

METHODS

VN individuals (n = 20) and those with mTBI (n = 19) participated. Those with mTBI were assessed 1-10 years post-injury (mean = 4.97 years), with the exception of one subject. Pattern VEP testing was employed using the DIOPSYS™ NOVA-TR system, with a 74 cd m baseline luminance. Luminance levels were reduced with five different neutral density (ND) filters (0.5, 1.0, 1.5, 2.0 and 2.5) and compared to the baseline response. All testing was performed under binocular-viewing conditions with full refractive correction in place.

RESULTS

In both groups, mean VEP amplitude reduced with decrease in luminance (p < 0.05). At each luminance level, the mean VEP amplitude was significantly lower in mTBI than in the VN population (p < 0.05). In both groups, the mean VEP latency increased progressively with reduction in luminance (p < 0.05), with it being significantly higher in mTBI than in the VN population (p < 0.05).

CONCLUSIONS

High luminance levels produced an optimal VEP response in both populations. VEP amplitude was robust, whereas latency progressively increased in both groups as luminance decreased. The latency increase with decreased luminance was significantly larger in those with mTBI, thus suggesting that latency can be used to differentiate reliably between VN individuals and those with mTBI.

摘要

目的

定量评估亮度对视功能正常者(VN)和轻度创伤性脑损伤(mTBI)患者视觉诱发电位(VEP)波幅和潜伏期的影响。

方法

纳入20名视功能正常者和19名mTBI患者。除1名受试者外,mTBI患者在受伤后1至10年接受评估(平均4.97年)。使用DIOPSYS™ NOVA - TR系统进行图形VEP测试,基线亮度为74 cd/m²。使用五个不同的中性密度(ND)滤光片(0.5、1.0、1.5、2.0和2.5)降低亮度水平,并与基线反应进行比较。所有测试均在双眼视条件下进行,并进行了完全屈光矫正。

结果

在两组中,VEP平均波幅均随亮度降低而减小(p < 0.05)。在每个亮度水平下,mTBI患者的VEP平均波幅均显著低于视功能正常者(p < 0.05)。在两组中,VEP平均潜伏期均随亮度降低而逐渐增加(p < 0.05),mTBI患者的潜伏期显著高于视功能正常者(p < 0.05)。

结论

高亮度水平在两组人群中均产生了最佳的VEP反应。VEP波幅稳定,而两组中潜伏期均随亮度降低而逐渐增加。mTBI患者中潜伏期随亮度降低的增加幅度显著更大,因此表明潜伏期可用于可靠地区分视功能正常者和mTBI患者。

相似文献

引用本文的文献

本文引用的文献

9
Gender impact on electrophysiological activity of the brain.性别对大脑电生理活动的影响。
Physiol Res. 2012;61(Suppl 2):S119-27. doi: 10.33549/physiolres.932421.
10
Objective assessment of the human visual attentional state.对人类视觉注意力状态的客观评估。
Doc Ophthalmol. 2013 Feb;126(1):29-44. doi: 10.1007/s10633-012-9357-7. Epub 2012 Oct 31.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验