Visual evoked potentials are useful in investigating the physiology and pathophysiology of the human visual system. Flash visual evoked potential (FVEP), though technically easier, has less clinical utility because it shows great variations in both latency and amplitude for normal subjects.
To study the effect of eye closure, low luminance, and monochromatic stimulation on the variability of FVEPs.
Subjects in self-reported good health in the age group of 18-30 years were divided into three groups. All participants underwent FVEP recording with eyes open and with white light at 0.6 J luminance (standard technique). Next recording was done in group 1 with closed eyes, group 2 with 1.2 and 20 J luminance, and group 3 with red and blue lights, while keeping all the other parameters constant. Two trials were given for each eye, for each technique. The same procedure was repeated at the same clock time on the following day.
Variation in FVEP latencies between the individuals (interindividual variability) and the variations within the same individual for four trials (intraindividual variability) were assessed using coefficient of variance (COV). The technique with lower COV was considered the better method.
Recording done with closed eyes, 0.6 J luminance, and monochromatic light (blue > red) showed lower interindividual and intraindividual variability in P2 and N2 as compared to standard techniques.
Low luminance flash stimulations and monochromatic light will reduce FVEP latency variability and may be clinically useful modifications of FVEP recording technique.
视觉诱发电位在研究人类视觉系统的生理学和病理生理学方面很有用。闪光视觉诱发电位(FVEP)虽然技术上更简单,但临床应用价值较小,因为正常受试者的潜伏期和波幅变化很大。
研究闭眼、低亮度和单色刺激对FVEP变异性的影响。
将18 - 30岁自我报告健康的受试者分为三组。所有参与者均在睁眼且白光亮度为0.6 J(标准技术)的条件下进行FVEP记录。接下来,第1组在闭眼状态下记录,第2组在亮度为1.2 J和20 J的条件下记录,第3组在红光和蓝光条件下记录,同时保持所有其他参数不变。每种技术对每只眼睛进行两次测试。第二天在相同的时钟时间重复相同的程序。
使用变异系数(COV)评估个体间FVEP潜伏期的差异(个体间变异性)以及同一受试者在四次测试中的差异(个体内变异性)。COV较低的技术被认为是更好的方法。
与标准技术相比,闭眼、0.6 J亮度和单色光(蓝光>红光)条件下记录的P2和N2的个体间和个体内变异性较低。