Suppr超能文献

孕期CT成像相关的临床指征及对胎儿的辐射剂量:一项回顾性研究

Clinical indications and radiation doses to the conceptus associated with CT imaging in pregnancy: a retrospective study.

作者信息

Woussen S, Lopez-Rendon X, Vanbeckevoort D, Bosmans H, Oyen R, Zanca F

机构信息

Department of Radiology, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium.

Department of Imaging and Pathology, University Hospitals Leuven, Leuven, Belgium.

出版信息

Eur Radiol. 2016 Apr;26(4):979-85. doi: 10.1007/s00330-015-3924-8. Epub 2015 Jul 23.

Abstract

OBJECTIVE

To perform an internal audit at a university hospital with the aim of evaluating the number, clinical indication and operating procedure of computed tomography (CT) performed on pregnant patients and of estimating the radiation doses to the conceptus.

METHODS

A retrospective review was conducted of all CT examinations performed in a single centre on pregnant patients between January 2008 and July 2013. The radiation doses to the conceptus were estimated. The results were compared with published data.

RESULTS

The number of CT examinations during pregnancy increased from 3-4 per year in 2008-2011 to 11 per year in 2012. The mean estimated conceptus radiation dose was considered negligible for CT of the head and cervical spine, being less than 0.01 mGy, and for CT of the chest, less than 0.1 mGy. The estimated conceptus radiation dose from abdominopelvic CT was on average 28.7 mGy (range 6.7-60.5 mGy).

CONCLUSIONS

The number of CT scans of pregnant patients increased threefold during the last few years. Most clinical indications and doses were in line with good clinical practice and literature; only in two cases the dose to the conceptus was higher than 50 mGy.

KEY POINTS

• An increase in CT imaging of pregnant patients is of concern. • Clinical indications were in line with good practice. • Estimated conceptus doses were lower or similar to published data. • Internal guidelines for appropriate use of imaging during pregnancy should be established.

摘要

目的

在一家大学医院开展内部审核,旨在评估对孕妇进行的计算机断层扫描(CT)的数量、临床指征及操作流程,并估算胎儿所受辐射剂量。

方法

对2008年1月至2013年7月间在单一中心对孕妇进行的所有CT检查进行回顾性分析。估算胎儿所受辐射剂量。将结果与已发表数据进行比较。

结果

孕期CT检查数量从2008 - 2011年的每年3 - 4次增加到2012年的每年11次。对于头部和颈椎CT,估算的胎儿平均辐射剂量可忽略不计,低于0.01 mGy,胸部CT低于0.1 mGy。腹部盆腔CT估算的胎儿辐射剂量平均为28.7 mGy(范围6.7 - 60.5 mGy)。

结论

在过去几年中,孕妇CT扫描数量增加了两倍。大多数临床指征和剂量符合良好临床实践及文献报道;仅两例胎儿所受剂量高于50 mGy。

关键点

• 孕妇CT成像增加令人担忧。• 临床指征符合良好实践。• 估算的胎儿剂量低于或与已发表数据相似。• 应制定孕期影像合理使用的内部指南。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验