Department of Prosthodontics, Near East University Faculty of Dentistry, Lefkosa, Mersin10, Ankara, Turkey.
Head Face Med. 2020 May 4;16(1):9. doi: 10.1186/s13005-020-00225-3.
There is no consensus in the literature regarding the impression procedures in the presence of multiple and angulated implants.
Three maxillary master models with 6 implants bilaterally positioned in anterior, premolar and molar regions were fabricated. In model 1, all implants were placed in parallel; in models 2 and 3, anterior implants were buccally inclined and posterior implants were distally inclined in 10- and 20-degrees, respectively. Three different impression copings (hexed, non-hex, multi-unit) and two different impression techniques (splinting and non-splinting) were tested. A total of 180 impressions (n = 10 per group) were made using mono-phase vinyl poly-siloxane. Master models and duplicate casts were scanned by a 5-axis laboratory scanner and data were transferred to a software program for the alignment of master and duplicate copings. Coronal and angular deviations were calculated, and data were statistically analyzed.
For angulated models, the lowest deviation values were detected at the splinted non-hex coping group (P < 0.05).
Implant angulation, impression coping type, and splinting the impression copings had significant effects on the accuracy of impressions.
Not applicable.
在存在多个和倾斜植入物的情况下,文献中没有关于印模程序的共识。
制作了三个带有 6 个种植体的上颌模型,这些种植体分别位于前牙、前磨牙和磨牙区域的双侧。在模型 1 中,所有种植体都被平行放置;在模型 2 和 3 中,前牙种植体颊向倾斜,后牙种植体分别向远中倾斜 10 度和 20 度。测试了三种不同的印模帽(六角、非六角、多单位)和两种不同的印模技术(加力和不加力)。使用单相乙烯基聚硅氧烷共制作了 180 个印模(每组 10 个)。主模型和复制模型通过 5 轴实验室扫描仪进行扫描,并将数据传输到软件程序中,用于对齐主模型和复制模型。计算了冠状和角度偏差,并对数据进行了统计学分析。
对于倾斜模型,在加力的非六角印模帽组中检测到最低的偏差值(P<0.05)。
种植体倾斜角度、印模帽类型以及加力印模帽对印模的准确性有显著影响。
不适用。