Comparison of interlaboratory results for blood lead with results from a definitive method.

作者信息

Boone J, Hearn T, Lewis S

出版信息

Clin Chem. 1979 Mar;25(3):389-93.

PMID:262177
Abstract

Results reported by 113 participants in the Blood Lead Proficiency Testing Program conducted by the Center for Disease Control were compared with those obtained by the National Bureau of Standards (NBS) with a definitive methods (mass spectroscopy-isotopic dilution) for blood lead analyses. Data were compiled from the results obtained for 12 whole-blood samples containing 1.5 g of disodium EDTA per liter. Twelve separate blood samples were obtained from cattle which had been given lead nitrate orally. Lead concentrations in the samples ranged from 0.628 to 4.93 mumol/L (130-1020 micrograms/L) as determined by NBS. The methods used by laboratories were classified according to six basic groups: anodic stripping voltametry; and atomic absorption spectroscopy in which either extraction, carbon rod, graphite furnace, tantalum strip, or Delves cup was used. For results obtained in each group a linear regression analyses of laboratory values was made on the basis of NBS values. In comparison to the definitive method, most field methods for blood lead tended to overestimate the lead concentration when the actual lead concentration was less than 1.96 mumol/L (400 micrograms/L) and to underestimate the lead concentration when the actual lead concentration was greater than 2.45 mumol/L (500 micrograms/L).

摘要

相似文献

1
Comparison of interlaboratory results for blood lead with results from a definitive method.
Clin Chem. 1979 Mar;25(3):389-93.
2
Graphite furnace atomic absorption spectroscopic measurement of blood lead in matrix-matched standards.石墨炉原子吸收光谱法测定基体匹配标准物质中的血铅含量。
Clin Chem. 1994 Sep;40(9):1730-4.
3
Disparities in clinical laboratory performance for blood lead analysis.血铅分析临床实验室检测结果的差异。
Arch Pediatr Adolesc Med. 1996 Jun;150(6):609-14. doi: 10.1001/archpedi.1996.02170310043008.
4
Monitoring human exposure to lead: an assessment of current laboratory performance for the determination of blood lead.监测人体铅暴露:对当前测定血铅实验室性能的评估。
Environ Res. 1992 Apr;57(2):149-62. doi: 10.1016/s0013-9351(05)80075-1.
5
Improved sample preparation for accurate determination of low concentrations of lead in whole blood by graphite furnace analysis.通过石墨炉分析改进全血中低浓度铅的准确测定的样品制备方法。
Clin Chem. 1991 Apr;37(4):515-9.
6
Blood lead proficiency testing: overview of the federally sponsored program in the U.S.
J Int Fed Clin Chem. 1993 Sep;5(4):158-61.
7
[Interlaboratory quality control for the determination of blood lead. Initial experiences in Tuscany].[血铅测定的实验室间质量控制。托斯卡纳的初步经验]
Quad Sclavo Diagn. 1983 Sep;19(3):301-12.
8
Screening for lead poisoning in an urban pediatric clinic using samples obtained by fingerstick.在城市儿科诊所使用手指采血样本筛查铅中毒。
Pediatrics. 1994 Aug;94(2 Pt 1):174-9.
9
Interlaboratory results for blood lead proficiency testing program in Thailand.
J Med Assoc Thai. 1999 Dec;82(12):1247-53.
10
Determination of lead in blood--an interlaboratory study.血液中铅含量的测定——一项实验室间研究。
Sci Total Environ. 1988 Apr;71(1):125-30. doi: 10.1016/0048-9697(88)90306-3.

引用本文的文献

1
Measurement Challenges at Low Blood Lead Levels.低血铅水平下的测量挑战。
Pediatrics. 2017 Aug;140(2). doi: 10.1542/peds.2017-0272. Epub 2017 Jul 17.
2
Storage and preservation of blood and urine for trace element analysis. A review.用于微量元素分析的血液和尿液的储存与保存。综述。
Biol Trace Elem Res. 1995 Aug-Sep;49(2-3):187-210. doi: 10.1007/BF02788968.
3
Lead poisoning from retained bullets. Pathogenesis, diagnosis, and management.滞留子弹导致的铅中毒。发病机制、诊断与处理
Ann Surg. 1982 Mar;195(3):305-13. doi: 10.1097/00000658-198203000-00010.
4
Hemolyzed, lyophilized bovine blood for quality control of lead determination of human whole blood.
Bull Environ Contam Toxicol. 1985 Sep;35(3):380-5. doi: 10.1007/BF01636526.
5
Lead absorption in indoor firing range users.室内射击场使用者的铅吸收情况。
Am J Public Health. 1989 Aug;79(8):1029-32. doi: 10.2105/ajph.79.8.1029.