Bactericidal efficacy of tissue tolerable plasma on microrough titanium dental implants: An in-vitro-study.

作者信息

Preissner Saskia, Wirtz Henrik C, Tietz Anne-Kristin, Abu-Sirhan Shady, Herbst Sascha R, Hartwig Stefan, Pierdzioch Philipp, Schmidt-Westhausen Andrea Maria, Dommisch Henrik, Hertel Moritz

机构信息

Department of Operative and Preventive Dentistry, Charité Universitätsmedizin Berlin, Aßmannshauser Str. 4-6, 14197, Berlin, Germany.

Department of Periodontology and Synoptic Dentistry, Charité Universitätsmedizin Berlin, Aßmannshauser Str. 4-6, 14197, Berlin, Germany.

出版信息

J Biophotonics. 2016 Jun;9(6):637-44. doi: 10.1002/jbio.201500189. Epub 2015 Sep 9.

Abstract

Surface decontamination remains challenging in peri-implant infection therapy. To investigate the bactericidal efficacy of tissue tolerable plasma, S. mitis biofilms were created in vitro on 32 microrough titanium dental implants. Biofilm imaging was performed by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). The implants were either rinsed with 1% NaCl as negative control (C) or irradiated with a diode laser (DL) for 60 sec as positive control or plasma (TTP60, TTP120) for 60 or 120 sec. Subsequently, colony forming units (CFU) were counted. Post-treatment, implants were further examined using fluorescence microscopy (FM). Median CFU counts differed significantly between TTP60, TTP120 and C (2.19 and 2.2 vs. 3.29 log CFU/ml; p = 0.012 and 0.024). No significant difference was found between TTP60 and TTP120 (p = 0.958). Logarithmic reduction factors were (TTP60) 2.21, (TTP120) 1.93 and (DL) 0.59. Prior to treatment, CLSM and SEM detected adhering bacteria. Post-treatment FM recorded that the number of dead cells was higher using TTP compared to DL and C. In view of TTP's effectiveness, regardless of resistance patterns and absence of surface alteration, its use in peri-implant infection therapy is promising. The results encourage conducting clinical studies to investigate its impact on relevant parameters.

摘要

在种植体周围感染治疗中,表面去污仍然具有挑战性。为了研究组织耐受等离子体的杀菌效果,在32个微粗糙钛牙科种植体上体外创建了缓症链球菌生物膜。通过共聚焦激光扫描显微镜(CLSM)和扫描电子显微镜(SEM)进行生物膜成像。种植体要么用1%氯化钠冲洗作为阴性对照(C),要么用二极管激光(DL)照射60秒作为阳性对照,要么用等离子体(TTP60、TTP120)照射60秒或120秒。随后,计算菌落形成单位(CFU)。处理后,使用荧光显微镜(FM)对种植体进行进一步检查。TTP60、TTP120和C之间的CFU计数中位数有显著差异(2.19和2.2对3.29 log CFU/ml;p = 0.012和0.024)。TTP60和TTP120之间未发现显著差异(p = 0.958)。对数减少因子分别为(TTP60)2.21、(TTP120)1.93和(DL)0.59。治疗前,CLSM和SEM检测到有黏附细菌。治疗后,FM记录显示,与DL和C相比,使用TTP时死细胞数量更多。鉴于TTP的有效性,无论耐药模式如何且不存在表面改变,其在种植体周围感染治疗中的应用前景广阔。这些结果鼓励开展临床研究以调查其对相关参数的影响。