To improve the accuracy and precision of tracer kinetic model parameter estimates for use in dynamic contrast enhanced (DCE) MRI studies of solid tumors.
Quantitative DCE-MRI requires an estimate of precontrast T1 , which is obtained prior to fitting a tracer kinetic model. As T1 mapping and tracer kinetic signal models are both a function of precontrast T1 it was hypothesized that its joint estimation would improve the accuracy and precision of both precontrast T1 and tracer kinetic model parameters.
Accuracy and/or precision of two-compartment exchange model (2CXM) parameters were evaluated for standard and joint fitting methods in well-controlled synthetic data and for 36 bladder cancer patients. Methods were compared under a number of experimental conditions.
In synthetic data, joint estimation led to statistically significant improvements in the accuracy of estimated parameters in 30 of 42 conditions (improvements between 1.8% and 49%). Reduced accuracy was observed in 7 of the remaining 12 conditions. Significant improvements in precision were observed in 35 of 42 conditions (between 4.7% and 50%). In clinical data, significant improvements in precision were observed in 18 of 21 conditions (between 4.6% and 38%).
Accuracy and precision of DCE-MRI parameter estimates are improved when signal models are fit jointly rather than sequentially. Magn Reson Med 76:1270-1281, 2016. © 2015 Wiley Periodicals, Inc.
提高示踪剂动力学模型参数估计的准确性和精确性,以用于实体肿瘤的动态对比增强(DCE)磁共振成像(MRI)研究。
定量DCE-MRI需要在拟合示踪剂动力学模型之前估计对比前T1值。由于T1映射和示踪剂动力学信号模型均是对比前T1的函数,因此推测其联合估计将提高对比前T1和示踪剂动力学模型参数的准确性和精确性。
在控制良好的合成数据以及36例膀胱癌患者中,针对标准拟合方法和联合拟合方法评估双室交换模型(2CXM)参数的准确性和/或精确性。在多种实验条件下对方法进行比较。
在合成数据中,联合估计在42种情况中的30种情况下使估计参数的准确性有统计学显著提高(提高幅度在1.8%至49%之间)。在其余12种情况中的7种情况下观察到准确性降低。在42种情况中的35种情况下观察到精确性有显著提高(在4.7%至50%之间)。在临床数据中,21种情况中的18种情况下观察到精确性有显著提高(在4.6%至38%之间)。
当联合而非顺序拟合信号模型时,DCE-MRI参数估计的准确性和精确性会提高。《磁共振医学》76:1270 - 1281, 2016。© 2015威利期刊公司。