Suppr超能文献

与传统开放技术相比,肱骨骨干骨折的微创钢板接骨术是否具有优势?

Is minimally invasive plating osteosynthesis for humeral shaft fracture advantageous compared with the conventional open technique?

作者信息

Wang Cheng, Li Jianmin, Li Ying, Dai Guofeng, Wang Manyi

机构信息

Shandong University, Qilu Hospital, Jinan City, Shandong, China.

Beijing Jishuitan Hospital, Peking University Fourth Clinical Medical College, Beijing, China.

出版信息

J Shoulder Elbow Surg. 2015 Nov;24(11):1741-8. doi: 10.1016/j.jse.2015.07.032.

Abstract

BACKGROUND

The minimally invasive plate osteosynthesis (MIPO) technique has been described and used effectively in humeral shaft fractures. However, the postoperative deformity resulting from malreduction with the minimally invasive technique has not received adequate attention. The purpose of this study was to evaluate the postoperative malrotation and the functional results of the MIPO technique and conventional plating in open reduction and internal fixation after humeral shaft fracture.

METHODS

A prospective cohort research was performed; 53 cases of humeral shaft fractures in a level I trauma center were included and allocated into group I for open reduction and internal fixation or group II for MIPO. Computed tomography was used to measure the postoperative malrotation. The status of the union, functional scoring, and muscle strength were recorded at 12 months after surgery.

RESULTS

Both groups exhibited satisfactory union results and final shoulder function scoring. Shoulder girdle musculature of both groups exhibited considerable strength loss with no obvious intergroup discrepancy, with greater internal rotation strength loss compared with external rotation. A significantly increased incidence of postoperative malrotation >20° was observed in the MIPO group (40.9% vs. 0%; P < .01). A linear correlation between postoperative malrotation and range of rotation loss was observed.

CONCLUSIONS

The MIPO technique might be advantageous as a cosmetic consideration; however, it did not improve postoperative function and strength restoration results more than the open technique. Moreover, MIPO was associated with greater postoperative malrotation, which was considered to be correlated with subsequent long-term shoulder degeneration.

摘要

背景

微创钢板接骨术(MIPO)已被描述并有效地应用于肱骨干骨折。然而,微创技术复位不良导致的术后畸形尚未得到充分关注。本研究的目的是评估肱骨干骨折切开复位内固定术后MIPO技术和传统钢板固定的术后旋转不良情况及功能结果。

方法

进行一项前瞻性队列研究;纳入一级创伤中心的53例肱骨干骨折患者,并分为I组接受切开复位内固定或II组接受MIPO。使用计算机断层扫描测量术后旋转不良情况。在术后12个月记录骨愈合情况、功能评分和肌肉力量。

结果

两组均显示出满意的骨愈合结果和最终肩部功能评分。两组的肩胛带肌肉组织均出现明显的力量损失,组间差异不明显,内旋力量损失比外旋更大。MIPO组术后旋转不良>20°的发生率显著增加(40.9%对0%;P<.01)。观察到术后旋转不良与旋转丧失范围之间存在线性相关性。

结论

从美观角度考虑,MIPO技术可能具有优势;然而,与切开技术相比,它并没有更能改善术后功能和力量恢复结果。此外,MIPO与更大的术后旋转不良相关,这被认为与随后的长期肩部退变有关。