可变附件形状和矫治器材料对矫治器固位的影响。

Effects of variable attachment shapes and aligner material on aligner retention.

作者信息

Dasy Hiltrud, Dasy Andreas, Asatrian Greg, Rózsa Noémi, Lee Hao-Fu, Kwak Jin Hee

机构信息

a   Postgraduate Student, Section of Orthodontics, School of Dentistry, University of California, Los Angeles, Calif.

b   Dental Student, School of Dentistry, University of California, Los Angeles, Calif.

出版信息

Angle Orthod. 2015 Nov;85(6):934-40. doi: 10.2319/091014-637.1.

Abstract

OBJECTIVE

To evaluate the retention of four types of aligners on a dental arch with various attachments.

MATERIALS AND METHODS

For this study, three casts were manufactured, two of which contained attachments (ellipsoid and beveled), and one without any attachments to serve as a control. Four types of aligners were thermoformed: Clear-Aligner (CA)-soft, CA-medium, and CA-hard, with various thicknesses, and Essix ACE. Measurements of vertical displacement force during aligner removal were performed with the Gabo Qualimeter Eplexor. Means and standard deviations were next compared between different aligner thicknesses and attachment shapes.

RESULTS

CA-soft, CA-medium, and CA-hard did not present a significant increase in retention, except when used in the presence of attachments. Additionally, CA-medium and CA-hard required significantly more force for removal. Essix ACE demonstrated a significant decrease in retention when used with ellipsoid attachments. The force value for Essix ACE removal from the cast with beveled attachments was comparable to that of CA-medium. Forces for aligner removal from the model without attachments showed a linear trend. Essix ACE did not show a continuous increase in retention for each model. Overall, ellipsoid attachments did not present a significant change in retention. In contrast, beveled attachments improved retention.

CONCLUSIONS

Ellipsoid attachments had no significant influence on the force required for aligner removal and hence on aligner retention. Essix ACE showed significantly less retention than CA-hard on the models with attachments. Furthermore, beveled attachments were observed to increase retention significantly, compared with ellipsoid attachments and when using no attachments.

摘要

目的

评估四种类型的矫治器在带有不同附件的牙弓上的固位情况。

材料与方法

本研究制作了三个模型,其中两个包含附件(椭圆形和斜面形),一个不包含任何附件作为对照。热压成型四种类型的矫治器:透明矫治器(CA)-软质、CA-中质和CA-硬质,具有不同厚度,以及Essix ACE。使用Gabo Qualimeter Eplexor测量矫治器移除过程中的垂直位移力。接下来比较不同矫治器厚度和附件形状之间的均值和标准差。

结果

CA-软质、CA-中质和CA-硬质在固位方面没有显著增加,除非在有附件的情况下使用。此外,CA-中质和CA-硬质移除时需要显著更多的力。Essix ACE与椭圆形附件一起使用时固位力显著下降。从带有斜面附件的模型上移除Essix ACE的力值与CA-中质相当。从无附件模型上移除矫治器的力呈线性趋势。Essix ACE在每个模型上的固位力并没有持续增加。总体而言,椭圆形附件在固位方面没有显著变化。相比之下,斜面附件改善了固位。

结论

椭圆形附件对移除矫治器所需的力以及因此对矫治器固位没有显著影响。在有附件的模型上,Essix ACE的固位力明显低于CA-硬质。此外,与椭圆形附件和不使用附件相比,观察到斜面附件显著增加了固位力。