Suppr超能文献

机械取栓术后使用双能CT诊断急性缺血

Diagnosis of acute ischemia using dual energy CT after mechanical thrombectomy.

作者信息

Gariani Joanna, Cuvinciuc Victor, Courvoisier Delphine, Krauss Bernhard, Mendes Pereira Vitor, Sztajzel Roman, Lovblad Karl-Olof, Vargas Maria Isabel

机构信息

Department of Radiology, Geneva University Hospitals, Geneva, Switzerland.

Department of Neuroradiology, Geneva University Hospitals, Geneva, Switzerland.

出版信息

J Neurointerv Surg. 2016 Oct;8(10):996-1000. doi: 10.1136/neurintsurg-2015-011988. Epub 2015 Nov 3.

Abstract

BACKGROUND AND PURPOSE

To assess the performance of dual energy unenhanced CT in the detection of acute ischemia after mechanical thrombectomy.

METHODS

Retrospective study, approved by the local institutional review board, including all patients that underwent intra-arterial thrombectomy in our institution over a period of 2 years. The presence of acute ischemia and hemorrhage was evaluated by three readers. Sensitivity and specificity of the non-contrast CT weighted sum image (NCCT) and the virtual non-contrast reconstructed image (VNC) were estimated and compared using generalized estimating equations to account for the non-independence of regions in each patient.

RESULTS

58 patients (27 women and 31 men; mean age 70.4 years) were included in the study, yielding 580 regions of interest. Sensitivity and specificity in detecting acute ischemia were higher for all readers when using VNC, with a significant increase in sensitivity for two readers (p<0.001 and 0.01) and a significant increase in specificity in one reader (p<0.001). Specificity in detecting hemorrhage was excellent for all readers.

CONCLUSIONS

Dual energy unenhanced CT VNC images were superior in the identification of acute ischemia in comparison with NCCT.

摘要

背景与目的

评估双能非增强CT在机械取栓术后急性缺血检测中的性能。

方法

回顾性研究,经当地机构审查委员会批准,纳入本机构2年内接受动脉内取栓术的所有患者。由三位阅片者评估急性缺血和出血的情况。使用广义估计方程估计并比较非增强CT加权和图像(NCCT)与虚拟非增强重建图像(VNC)的敏感性和特异性,以考虑每位患者各区域的非独立性。

结果

本研究纳入58例患者(27例女性和31例男性;平均年龄70.4岁),共产生580个感兴趣区域。使用VNC时,所有阅片者检测急性缺血的敏感性和特异性均更高,两位阅片者的敏感性显著增加(p<0.001和0.01),一位阅片者的特异性显著增加(p<0.001)。所有阅片者检测出血的特异性均极佳。

结论

与NCCT相比,双能非增强CT的VNC图像在识别急性缺血方面更具优势。