Nawaz Allah, Waqar Sadaf, Khan Ahsan, Mansoor Rashid, Butt Usman Ismat, Ayyaz Mahmood
Department of Surgical Unit 2, Services Institute of Medical Sciences/Services Hospital, Lahore.
J Coll Physicians Surg Pak. 2015 Dec;25(12):870-3.
To compare the results between harmonics scalpel and electrocautery use in axillary dissection for carcinoma breast.
Randomized controlled trial.
Department of Surgery, Services Hospital, Lahore, from December 2013 to June 2014.
Eighty patients fulfilling the inclusion criteria were selected and equally divided in two groups. Axillary dissection for carcinoma breast was performed by using the harmonic scalpel in one group and by using electrocautery in the other group. Total mean axillary drain output and frequency of axillary numbness were noted in both groups and compared.
All the patients were females with mean age of 53.52 ± 9.8. Mean axillary drain output in harmonic scalpel group was 167.75 ± 43.90 as compared to 310.00 ± 60.09 in electrocautery group while only 12.5% of patients were positive for axillary numbness in harmonic scalpel group as compared to 100% of patients who were positive for electrocautery group.
Use of harmonic scalpel in axillary dissection resulted in decreased total mean axillary drain output and lowered frequency of axillary numbness when compared to utilizing electrocautery.
比较在乳腺癌腋窝清扫术中使用谐波手术刀和电灼术的结果。
随机对照试验。
2013年12月至2014年6月,拉合尔服务医院外科。
选择80例符合纳入标准的患者,平均分为两组。一组使用谐波手术刀进行乳腺癌腋窝清扫术,另一组使用电灼术。记录两组患者腋窝引流总量的平均值和腋窝麻木的发生率,并进行比较。
所有患者均为女性,平均年龄为53.52±9.8岁。谐波手术刀组腋窝引流总量的平均值为167.75±43.90,而电灼术组为310.00±60.09;谐波手术刀组仅有12.5%的患者出现腋窝麻木,而电灼术组为100%。
与使用电灼术相比,在腋窝清扫术中使用谐波手术刀可减少腋窝引流总量的平均值,并降低腋窝麻木的发生率。