Deo S V S, Shukla N K, Asthana S, Niranjan B, Srinivas G
Department of Surgical Oncology, Institute Rotary Cancer Hospital, All India Institute of Medical Sciences, New Delhi.
Singapore Med J. 2002 May;43(5):226-8.
The harmonic scalpel is recently emerging as an alternative surgical tool for dissection and haemostasis and has been extensively used in the field of minimally invasive surgery. We studied the utility and advantages of this instrument over electrocautery for performing modified radical mastectomy.
The operative and morbidity details of twenty-three breast cancer patients who underwent modified radical mastectomy using the harmonic scalpel were compared with 23 matched controls operated with electrocautery by the same surgical team.
There was no significant difference in the operating time between the harmonic scalpel and electrocautery group (104 and 100 mins, p > 0.05). The blood loss (60 +/- 35 ml and 294 +/- 155, p < 0.001) and drainage volume (590 +/- 430 ml and 1,085 +/- 690 ml, p < 0.001) were significantly lower in the harmonic scalpel group. There was a significant reduction of drain days in harmonic scalpel group (mean five and nine days, p < 0.05). There was no significant difference in the seroma rate between two groups (16% and 22%).
Modified radical mastectomy using harmonic scalpel is feasible and learning curve is short. Harmonic scalpel significantly reduces the blood loss and duration of drainage as compared to electrocautery.
谐波手术刀作为一种用于解剖和止血的新型手术工具,最近开始出现,并已在微创手术领域广泛应用。我们研究了该器械在进行改良根治性乳房切除术中相对于电灼术的效用和优势。
将23例行改良根治性乳房切除术的乳腺癌患者使用谐波手术刀的手术及发病情况细节,与同一手术团队采用电灼术的23例匹配对照患者进行比较。
谐波手术刀组与电灼术组的手术时间无显著差异(分别为104分钟和100分钟,p>0.05)。谐波手术刀组的失血量(60±35毫升和294±155毫升,p<0.001)和引流量(590±430毫升和1085±690毫升,p<0.001)显著更低。谐波手术刀组的引流天数显著减少(平均分别为5天和9天,p<0.05)。两组之间的血清肿发生率无显著差异(分别为16%和22%)。
使用谐波手术刀进行改良根治性乳房切除术是可行的,且学习曲线短。与电灼术相比,谐波手术刀显著减少了失血量和引流时间。